Radiation Planning Assistant - A Streamlined, Fully Automated Radiotherapy Treatment Planning System
Published on: April 11, 2018
VMAT to arclet plan conversion in a treatment planning system : Feasibility and dosimetric relationship between VMAT,
Yvonne Dzierma1, Norbert Licht2, Ian Norton3
1Department of Radiotherapy, Saarland University Medical Center, Kirrberger Straße 6.5, 66421, Homburg/Saar, Germany. Yvonne.dzierma@uks.eu.
Aim:
The aim of this study was to make dynamic rotation treatment with mARC available for the non-dedicated Philips Pinnacle treatment planning system by converting SmartArc plans, offering insight into the relationship between SmartArc, mARC, and stationary field irradiation.
Methods:
A scripting solution is presented that can be run in the Pinnacle system. This allows for the conversion of SmartArc plans into mARC format. The dose distribution of the converted mARC plan can be evaluated both in the form of a "real" mARC plan with arclets and-as is generally done in treatment planning systems certified for mARC planning-by approximating the arclets as stationary fields. We present the proof of principle and dosimetric comparisons.
Results:
The converted plans were irradiated without problems. For the measured 3D dose distributions, on average over 90 % points agreed with the calculated dose distributions (mARC and stationary field plans) within the gamma criteria of 3 % deviation in the local dose, 3-mm distance to agreement, for all dose values above 10 % of the maximum. The agreement between the three calculated dose distributions (SmartArc with both converted plans) was above 87 % (above 92 % when comparing mARC with stationary fields).
Conclusion:
Our solution offers the possibility of mARC planning in Pinnacle. The dose comparisons furthermore prove that the dosimetric differences between SmartArc and mARC, when appropriately translated, are minor.
More Related Videos
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
05:18Author Spotlight: Improving Radiation Therapy Access with Radiation Planning Assistant
Published on: October 6, 2023
Related Concept Videos
Mesh Analysis
A fundamental concept in mesh analysis is the definition of meshes and mesh currents. A mesh is a closed...
Mesh Analysis for AC Circuits
The process of harmonizing these impedances begins with a clear understanding of the input and output signals. Once these signals are known, the...