Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Fluid bolus therapy: monitoring and predicting fluid responsiveness
Andrea Carsetti1, Maurizio Cecconi, Andrew Rhodes
1Department of Intensive Care Medicine, St George's University Hospitals NHS Foundation Trust and St George's University of London, London, UK.
Purpose Of Review:
When a condition of hypoperfusion has been identified, clinicians must decide whether fluids may increase blood flow or whether other therapeutic approaches are needed. For this purpose, several tests and parameters have been introduced in clinical practice to predict fluid responsiveness and guide therapy.
Recent Findings:
Fluid challenge is the gold standard test to assess the preload dependence of the patients. Moreover, several parameters and tests avoiding fluid administration are now available. Pulse pressure variation and stroke volume variation are based on heart-lung interaction and can be used to assess fluid responsiveness. These parameters have several limitations and can really be used in a limited number of critically ill patients. End-expiratory occlusion test and passive leg raising have been proposed to overcome these limitations. The aim of resuscitation is to increase blood flow and perfusion pressure. Dynamic arterial elastance has been recently proposed to predict the pressure response after fluid challenge in preload-dependent patients. Finally, the effects of volume expansion of hemodynamic parameters do not necessarily reach the microcirculation, which should also be assessed.
Summary:
Nowadays, several parameters are available to assess fluid responsiveness. Clinicians need to know all of them, with their limitations, without forgetting that the final aim of all therapies is to improve the microcirculation.
Related Concept Videos
Two-Compartment Open Model: IV Bolus Administration
The disparity between drug input and the sum of drug transfer rates between...
One-Compartment Open Model for IV Bolus Administration: General Considerations
The drug's presence in the body is defined by an equation representing the difference between the rates of drug entry and exit. Key parameters—elimination rate constant,...
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...
Heart Failure VI: Adjunct Therapies
Heart Failure VII: Nursing Interventions
One-Compartment Open Model for IV Bolus Administration: Estimation of Elimination Rate Constant, Half-Life and Volume of Distribution