Primary standards for measuring flow rates from 100 nl/min to 1 ml/min - gravimetric principle
Abstract:
Microflow and nanoflow rate calibrations are important in several applications such as liquid chromatography, (scaled-down) process technology, and special health-care applications. However, traceability in the microflow and nanoflow range does not go below 16 μl/min in Europe. Furthermore, the European metrology organization EURAMET did not yet validate this traceability by means of an intercomparison between different National Metrology Institutes (NMIs). The NMIs METAS, Centre Technique des Industries Aérauliques et Thermiques, IPQ, Danish Technological Institute, and VSL have therefore developed and validated primary standards to cover the flow rate range from 0.1 μl/min to at least 1 ml/min. In this article, we describe the different designs and methods of the primary standards of the gravimetric principle and the results obtained at the intercomparison for the upper flow rate range for the various NMIs and Bronkhorst High-Tech, the manufacturer of the transfer standards used.
More Related Videos
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
05:11High-precision Electromagnetic Flowmeter with Empty Pipe Detection via Complex Programmable Logic Device-based Waveform Recognition
Published on: June 27, 2025
Related Concept Videos
Pipe Flowrate Measurement
The orifice meter is a simple,...
Gravimetry: Overview
In precipitation gravimetry, the analyte is converted into a precipitate and weighed. For example, the silver content in a sample can be estimated by precipitating and...
Pipe Flowrate Measurement: Problem Solving
Precipitation Gravimetry
In determining nickel by gravimetric analysis, a precipitant of ethanolic dimethylglyoxime is added to a hot nickel salt solution. This is quickly followed by the dropwise addition of dilute ammonia solution until precipitation occurs. A...
Bernoulli's Equation: Problem Solving
The first step is to compute the cross-sectional areas of the pipe and the Venturi throat to analyze the pressure difference indicated by the pressure gauge. Next, the continuity equation is...
Conservation of Mass in Fixed, Nondeforming Control Volume
In the case of a sewer pipe, which can be modeled...