Related Experiment Video
Updated: Apr 4, 2026

Preparation and Friction Force Microscopy Measurements of Immiscible, Opposing Polymer Brushes
Published on: December 24, 2014
Influence of different lubricants on the retentive force of LOCATOR(®) attachments - an in vitro pilot study
Murali Srinivasan1, Martin Schimmel1,2, Mariko Kobayashi3
1Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland.
Objective:
The aim of this in vitro pilot study was to evaluate the influence of an artificial saliva (AS) lubricant on the retentive force of a stud-type attachment (LOCATOR(®) ) for implant overdentures (IODs).
Methods:
Twenty custom-made models simulating a two-IOD with parallel implant situation were fabricated using LOCATOR(®) attachments. The in vitro testing was carried out with an Instron(®) universal testing machine for a total of 10,000 insertion-removal cycles, for each model, in two different aqueous test mediums (Group 1: 0.9% sodium chloride solution (NaCl), n = 10; Group 2: AS, n = 10). Changes in the mean retentive force (F) were plotted against the cycle numbers #10, #100, #1000, #5000, and #10,000. Mixed regression models were applied for statistical analyses.
Results:
A mixed regression (not considering interactions) predicted, compared to cycle #10, higher retentive forces at cycles #100 (P < 0.0001), #1000 (P = 0.017), similar forces at #5000 (P = 0.277), and lower forces at #10,000 (P = 0.012); there was no overall effect of the medium (P = 0.159). A second statistical model, employing the interaction term "cycle##medium", confirmed similarly the effect. Although the interaction term was significant at cycle #100 (p = 0.045), there was no significant difference between the two groups (P = 0.140).
Conclusion:
In this in vitro pilot experiment, there was no difference in mean retentive forces of the LOCATOR(®) attachments when tested with either 0.9% NaCl or a Glandosane(®) -like artificial saliva lubricant. A larger scale study may still confirm the superiority of either lubricant for quasiclinical bench experiments.
More Related Videos
07:09In situ Compressive Loading and Correlative Noninvasive Imaging of the Bone-periodontal Ligament-tooth Fibrous Joint
Published on: March 7, 2014
09:48A Friction Testing-Bioreactor Device for Study of Synovial Joint Biomechanics, Mechanobiology, and Physical Regulation
Published on: June 2, 2022
Related Concept Videos
Bearings: Problem Solving
Design Example: Deciding Thickness of Lubricating Fluid in a Shaft
To calculate the required thickness of the lubricant layer, the tangential velocity at the shaft's surface must first be determined. This velocity is calculated by converting the rotational speed to angular velocity...
Journal Bearings
To better understand the concept of journal bearings, consider a rope winch with dry or...
Frictional Forces on Screws
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...