Related Experiment Video
Updated: Apr 4, 2026

A Rapid and Specific Microplate Assay for the Determination of Intra- and Extracellular Ascorbate in Cultured Cells
Published on: April 11, 2014
Determination of dopamine in presence of ascorbic acid and uric acid using poly (Spands Reagent) modified carbon
Y Veera Manohara Reddy1, V Prabhakara Rao1, A Vijaya Bhaskar Reddy1
1Department of Chemistry, Sri Venkateswara University, Tirupati 517502, Andhra Pradesh, India.
Abstract:
In this paper, we have fabricated a modified carbon paste electrode (CPE) by electropolymerisation of spands reagent (SR) onto surface of CPE using cyclic voltammetry (CV). The developed electrode was abbreviated as poly(SR)/CPE and the surface morphology of the modified electrode was studied by using scanning electron microscopy (SEM). The developed electrode showed higher electrocatalytic properties towards the detection of dopamine (DA) in 0.1M phosphate buffer solution (PBS) at pH7.0. The effect of pH, scan rate, accumulation time and concentration of dopamine was studied at poly(SR)/CPE. The poly(SR)/CPE was successfully used as a sensor for the selective determination of DA in presence of ascorbic acid (AA) and uric acid (UA) without any interference. The poly(SR)/CPE showed a good detection limit of 0.7 μM over the linear dynamic range of 1.6 μM to 16 μM, which is extremely lower than the reported methods. The prepared poly(SR)/CPE exhibited good stability, high sensitivity, better reproducibility, low detection limit towards the determination of DA. The developed method was also applied for the determination of DA in real samples.
Related Concept Videos
Complexometric EDTA Titration Curves
Polyprotic Acids