Related Experiment Video
Updated: Apr 4, 2026

Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots
Published on: May 21, 2017
Chest Blunt Trauma: An Uncommon Cause of Aortic Stentless Bioprosthesis Dysfunction
Alberto Repossini1, Laura Giroletti1, Fabrizio Rosati1
1Division of Cardiac Surgery, University of Brescia Medical School, Brescia, Italy.
Abstract:
Acute leaflet rupture occurred in a Freedom Solo (Sorin Group, Milan, Italy) pericardial stentless aortic bioprosthesis after chest blunt trauma 8 years after valve replacement. Intraoperative findings revealed an acute tear of the right cusp at the level of the structural suture line. Pericardial leaflets were not degenerated at histologic analysis. Reoperation was easy, with simple removal of the prosthetic cusps, and a sutureless Perceval (Sorin Group) bioprosthesis was successfully implanted. This is the first reported case of an acute rupture of a stentless aortic bioprosthesis after a chest blunt trauma and the first histologic analysis of an 8-year-old Freedom Solo.
More Related Videos
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
14:14Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
Published on: December 11, 2017
Related Concept Videos
Mitral Stenosis III: Medical Management
Aneurysm III: Interprofessional Care
Aortic Regurgitation I: Introduction
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Aortic Regurgitation III: Medical Management