Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Gas Chromatography: Types of Detectors-II01:19

Gas Chromatography: Types of Detectors-II

1.4K
In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...
1.4K
High-Performance Liquid Chromatography: Types of Detectors01:15

High-Performance Liquid Chromatography: Types of Detectors

2.2K
The role of the detectors in High-Performance Liquid Chromatography (HPLC) is to analyze the solutes as they exit from the chromatographic column. The detector recognizes the solute's property and generates corresponding electrical signals, which are converted into a readable graph of the detector's response versus elution time called a chromatogram at the computer. There are several types of HPLC detectors, each with its own advantages and limitations, depending on the analyte...
2.2K
Mass Analyzers: Common Types01:19

Mass Analyzers: Common Types

1.9K
The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
1.9K
Gas Chromatography: Types of Detectors-I01:21

Gas Chromatography: Types of Detectors-I

2.0K
There are different types of detectors used in gas chromatography, each with its own specific properties that make it suitable for detecting certain types of analytes. The most commonly used detectors in GC are thermal conductivity detector (TCD), flame ionization detector (FID), and electron capture detector (ECD).
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
2.0K
Determination of Crystal Structures01:29

Determination of Crystal Structures

111
In the late 1800s, the revelation that light extended beyond visible wavelengths led to the discovery of X-rays by Wilhelm Roentgen. Recognized as high-energy electromagnetic radiation with short wavelengths, X-rays prompted exploration into their interaction with crystals. Max von Laue proposed in 1912 that the periodic arrangement of atoms, ions, or molecules in crystals would cause them to diffract X-rays, a hypothesis confirmed through experiments with copper sulfate and zinc sulfide...
111
Mass Spectrometers01:16

Mass Spectrometers

10.9K
This lesson details the instrumentation of a mass spectrometer—a physical instrument to perform mass spectrometry on analyte molecules and record the characteristic mass spectra. This is achieved via three chief functions:
10.9K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Solid-state dosimeters: a new approach for mammography measurements.

Medical physics·2015
Same author

Characterization of scatter in digital mammography from use of Monte Carlo simulations and comparison to physical measurements.

Medical physics·2014
Same author

Characterization of scatter in digital mammography from physical measurements.

Medical physics·2014
Same author

Evaluation of new data processing algorithms for planar gated ventriculography (MUGA).

Journal of applied clinical medical physics·2009
Same author

An opportunity for radiology: progress report following the second educational summit.

Radiology·2007
Same author

Characterization of a fiber-optic-coupled radioluminescent detector for application in the mammography energy range.

Medical physics·2007

Related Experiment Video

Updated: Apr 4, 2026

Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator
07:31

Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator

Published on: May 9, 2014

12.3K

Meaningful Data or Just Measurements? Differences Between Ionization Chamber and Solid-State Detectors

Libby F Brateman1, Philip H Heintz2

  • 1Department of Radiology, University of Florida College of Medicine, Gainesville, Florida.

Journal of the American College of Radiology : JACR
|September 11, 2015
PubMed
Summary

No abstract available in PubMed .

More Related Videos

Coulomb Explosion Imaging as a Tool to Distinguish Between Stereoisomers
08:51

Coulomb Explosion Imaging as a Tool to Distinguish Between Stereoisomers

Published on: August 18, 2017

11.1K
Photoelectron Imaging of Anions Illustrated by 310 Nm Detachment of F−
06:53

Photoelectron Imaging of Anions Illustrated by 310 Nm Detachment of F−

Published on: July 27, 2018

9.3K

Related Experiment Videos

Last Updated: Apr 4, 2026

Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator
07:31

Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator

Published on: May 9, 2014

12.3K
Coulomb Explosion Imaging as a Tool to Distinguish Between Stereoisomers
08:51

Coulomb Explosion Imaging as a Tool to Distinguish Between Stereoisomers

Published on: August 18, 2017

11.1K
Photoelectron Imaging of Anions Illustrated by 310 Nm Detachment of F−
06:53

Photoelectron Imaging of Anions Illustrated by 310 Nm Detachment of F−

Published on: July 27, 2018

9.3K