Quantitative Measurement of Split of the Second Heart Sound (S2)
Abstract:
This study proposes a quantitative measurement of split of the second heart sound (S2) based on nonstationary signal decomposition to deal with overlaps and energy modeling of the subcomponents of S2. The second heart sound includes aortic (A2) and pulmonic (P2) closure sounds. However, the split detection is obscured due to A2-P2 overlap and low energy of P2. To identify such split, HVD method is used to decompose the S2 into a number of components while preserving the phase information. Further, A2s and P2s are localized using smoothed pseudo Wigner-Ville distribution followed by reassignment method. Finally, the split is calculated by taking the differences between the means of time indices of A2s and P2s. Experiments on total 33 clips of S2 signals are performed for evaluation of the method. The mean ± standard deviation of the split is 34.7 ± 4.6 ms. The method measures the split efficiently, even when A2-P2 overlap is ≤ 20 ms and the normalized peak temporal ratio of P2 to A2 is low (≥ 0.22). This proposed method thus, demonstrates its robustness by defining split detectability (SDT), the split detection aptness through detecting P2s, by measuring up to 96 percent. Such findings reveal the effectiveness of the method as competent against the other baselines, especially for A2-P2 overlaps and low energy P2.
More Related Videos
09:05Transthoracic Speckle Tracking Echocardiography for the Quantitative Assessment of Left Ventricular Myocardial Deformation
Published on: October 20, 2016
11:13Quantification of Mouse Heart Left Ventricular Function, Myocardial Strain, and Hemodynamic Forces by Cardiovascular Magnetic Resonance Imaging
Published on: May 24, 2021
Related Concept Videos
Heart Sounds
Auscultation is the process of listening to these internal body sounds using a stethoscope. The heart produces four types of sounds, but only two—S1 and S2—can usually be heard with a stethoscope.
S1, also known as the "lub" sound, is caused by the closure of atrioventricular (A-V)...
Measurement of Blood Pressure
Special considerations while measuring pulse
Assessment of the Cardiovascular System IV: Auscultation
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Pulse
The pulse serves as a clinical...
