Related Experiment Video
Updated: Apr 4, 2026

Magnetic Resonance Spectroscopy of live Drosophila melanogaster using Magic Angle Spinning
Published on: April 15, 2010
An optimal double-magic flip angle for performing the distance measurement REDOR experiment on a spin S=1
E Nimerovsky1, A Haimovich1, A Goldbourt1
1School of Chemistry, Raymond and Beverly Sackler Faculty of Exact Sciences, Tel Aviv University, Ramat Aviv 69978, Tel Aviv, Israel.
Abstract:
Distance measurements between a half-spin and a quadrupolar S=1 spin having a small quadrupolar coupling constant can be performed using the rotational echo double resonance (REDOR) experiment. We derived an analytical expression for the probability of transitions between energy levels resulting from the application of an arbitrary pulse flip angle to the quadrupolar spin and consequently minimized the probability that populations of individual levels do not undergo a spin transition during the pulse. As a result we discovered that if the flip angle of the quadrupolar spin pulse is 109.47°, the maximal recoupling values are the largest possible and the signal reaches a maximum value of 8/9, larger than in the use of either a 90° pulse or a 180° pulse. In addition, the slope of the initial decay is higher than that of the 90° pulse. The recoupling signal can be modeled by an exact analytical formula in the ideal case and simulations show that the advantage of the 109.47° pulse is preserved when the quadrupolar coupling constant CQ has a finite value typical of (2)H and (6)Li spins (up to CQ~200kHz). Experimental results on two spin pairs, (2)H-(13)C and (6)Li-(13)C, demonstrate the validity and accuracy of this method.
More Related Videos
Related Concept Videos
Double Resonance Techniques: Overview
Spin decoupling is usually achieved by...
Spin–Spin Coupling Constant: Overview
Qualitatively, any spin plus-half nucleus polarizes the spins of its electrons to the minus-half state. Consequently, the paired electron in the hydrogen–carbon bond must...
Spin–Spin Coupling: Two-Bond Coupling (Geminal Coupling)
The central atom need not be NMR-active because its electrons are affected by the electron polarization of the spin-active atoms. However, spin information is transmitted less effectively than in one-bond coupling, and 2J values are usually weaker than 1J values. The energy of...
Rolling Without Slipping
Equation of Motion: Rotation About a Fixed Axis
The tangential component is dependent on the direction of the angular acceleration of the flywheel. The tangential component of the acceleration propels the flywheel along its path. On the other hand,...
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...

