[Computational fluid dynamics analysis of the flow of four irrigations in root canal]
Ying Ma1, Jialong Han1, Haiyan Yu1
1Department of Stomatology, The Fourth Hospital of Harbin Medical University, Harbin 150001, China.
Objective:
To analyze the flow of four irrigations in a root canal with different needle-insertion depth by using a computational fluid dynamics (CFD) model in order to provide a reference to the needle placement in clinical practice.
Methods:
The density and viscosity of 5.25% sodium hypochlorite (A), 3% sodium hypochlorite (B), 17% ethylenediaminetetraacetic acid (EDTA, C), 2% chlorhexidine (D) were measured. A CFD model by ICEM software was used to simulate irrigant flow from an open-ended flat needle positioned at the depth of 1, 3, 5 mm to the physiological apical within the root canal. Velocity, wall shear stress and pressure in the root canal were evaluated after setting the computing conditions with FLUENT14.0 software.
Results:
All the wall shear stress generated by four fluids was at peak when the needle was positioned 1 mm to the physiological apical, which were 6.72 × 10³ Pa(A), 6.35 × 10³ Pa(B), 7.47 × 10³ Pa(C), 5.26 × 10³ Pa(D), respectively. With the distance increasing, wall shear stress gradually decreased. The wall shear stress of A, B, C, D was 2.31 × 10³, 2.05 × 10³, 2.59 × 10³ and 1.81 × 10³ Pa, respectively in 3 mm group. The wall shear stress of A, B, C, D was 2.16 × 10³, 1.91 × 10³, 2.42 × 10³, 1.71 × 10³ Pa, respectively in 5 mm group.
Conclusions:
It was recommended that the distance between the needle and physiological apical is 1-3 mm when flushing the root canal. The injection speed of 17% EDTA should be slower than that of the other three solutions.
Related Concept Videos
Uniform Depth Channel Flow
Conservation of Mass in Moving, Nondeforming Control Volume
In the context of a detention basin, the conservation of mass states that the total mass of water entering the basin must equal the mass leaving the basin plus any accumulation of...
Design Example: Design of an Irrigation Channel
Single Pipe Systems
In a Type I problem, fluid properties (density and viscosity), pipe characteristics (including diameter, length, and surface roughness), and the flow rate or average velocity are...
Gradually Varying Flow
Pipe Flowrate Measurement: Problem Solving