Tissue Doppler Imaging predicts central sleep apnea in patients with chronic heart failure: data from the Daunia
Michele Correale1, Natale Daniele Brunetti2, Lucia Forte2
1Cardiology Department, Ospedali Riuniti, Foggia, Italy.
Background:
Tissue Doppler imaging (TDI) is used to improve risk stratification in patients with chronic heart failure (CHF). So far, few studies have used this method to investigate the characteristics of subjects with CHF and Cheyne-Stokes breathing (CSB). The aim of this study was therefore to evaluate whether TDI assessment may predict the presence of CSB in patients with CHF.
Materials And Methods:
A total of 41 consecutive patients with CHF enrolled in the Daunia Heart Failure Registry underwent echocardiography assessment and nocturnal polygraphy to evaluate the presence of sleep apnea and CSB. Conventional echocardiography and TDI parameters were calculated. We have also quantified by TDI a combined index (EAS index) of diastolic and systolic performance: E'/(A' × S').
Results:
Subjects with evidence of CSB (N = 8) were characterized by lower values of A' (5·03 ± 2·64 vs. 7·88 ± 2·64 cm/s, P < 0·01). A' and EAS index values were related to Cheyne-Stokes episode rates (r = -0·49 and 0·52, P < 0·05 and <0·01 respectively), EAS index values also with the number of episodes of central apnea (r = 0·39, P < 0·05). A' values predicted the presence of CSB at poly-somnography examination with an OR 0·62 (95% CI 0·40-0·96, P < 0·05) even after correction for age and gender.
Conclusions:
Tissue Doppler imaging values (A') are associated with the presence of sleep apnea at nocturnal polygraphy.
More Related Videos
07:54Drug-Induced Sleep Endoscopy DISE with Target Controlled Infusion TCI and Bispectral Analysis in Obstructive Sleep Apnea
Published on: December 6, 2016
07:49Author Spotlight: Investigating HR-Dependent Cardiac Function in Mouse Models Through a Novel Atrial-Pacing Approach
Published on: July 21, 2023
Related Concept Videos
Sleep Apnea
The condition is more prevalent among...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Heart Failure VI: Adjunct Therapies
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...