The Tiotropium Safety and Performance in Respimat® (TIOSPIR®) Trial: Spirometry Outcomes
Antonio Anzueto1, Robert Wise2, Peter Calverley3
1Pulmonary/Critical Care, University of Texas Health Science Center, and South Texas Veterans Health Care System, 111E, 7400 Merton Minter Blvd, San Antonio, TX, 78229, USA. anzueto@uthscsa.edu.
Background:
Tiotropium Safety and Performance in Respimat® (TIOSPIR®) compared the safety and efficacy of tiotropium Respimat® and tiotropium HandiHaler® in patients with chronic obstructive pulmonary disease (COPD). A prespecified spirometry substudy compared the lung function efficacy between treatment groups.
Methods:
TIOSPIR® was a large-scale, long-term (2.3-year), event-driven, randomized, double-blind, parallel-group trial of 17,135 patients with COPD. In the spirometry substudy, trough forced expiratory volume in 1 second (FEV1) and forced vital capacity (FVC) were measured at baseline and every 24 weeks for the duration of the trial.
Results:
The substudy included 1370 patients who received once-daily tiotropium Respimat® 5 μg (n = 461), 2.5 μg (n = 464), or tiotropium HandiHaler® 18 μg (n = 445). Adjusted mean trough FEV1 (average 24-120 weeks) was 1.285, 1.258, and 1.295 L in the Respimat® 5 μg, 2.5 μg, and HandiHaler® 18 μg groups (difference versus HandiHaler® [95 % CI]: -10 [-38, 18] mL for Respimat® 5 μg and, -37 [-65, -9] mL for Respimat® 2.5 μg); achieving noninferiority to tiotropium HandiHaler® 18 μg for tiotropium Respimat® 5 but not for 2.5 μg (prespecified analysis). Adjusted mean trough FVC was 2.590, 2.544, and 2.593 L in the Respimat® 5 μg, 2.5 μg, and HandiHaler® 18 μg groups. The rates of FEV1 decline over 24 to 120 weeks were similar for the three treatment arms (26, 40, and 34 mL/year for the tiotropium Respimat® 5-μg, 2.5-μg, and HandiHaler® 18-μg groups). The rate of FEV1 decline in GOLD I + II patients was greater than in GOLD III + IV patients (46 vs. 23 mL/year); as well as in current versus ex-smokers, in patients receiving combination therapies at baseline versus not, and in those experiencing an exacerbation during the study versus not.
Conclusions:
The TIOSPIR® spirometry substudy showed that tiotropium Respimat® 5 μg was noninferior to tiotropium HandiHaler® 18 μg for trough FEV1, but Respimat® 2.5 μg was not. Tiotropium Respimat® 5 μg provides similar bronchodilator efficacy to tiotropium HandiHaler® 18 μg with comparable rates of FEV1 decline. The rate of FEV1 decline varied based on disease severity, with a steeper rate of decline observed in patients with moderate airway obstruction.
Trial Registration:
NCT01126437.
More Related Videos
Related Concept Videos
Antiasthma Drugs: Muscarinic Receptor Antagonists
Antimuscarinic agents compete with ACh for the same binding site on the muscarinic receptors. By binding to these receptors, they inhibit the downstream effects of ACh and block the parasympathetic...
Inhaled Medications
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...
Cholinergic Antagonists: Pharmacokinetics
Antiasthma Drugs: β2-Adrenoceptor Agonists
One class of bronchodilators includes β2-adrenoceptor agonists. These agents target the β2-adrenoceptors located on bronchial smooth muscle cells. By stimulating these receptors, β2-agonists induce...
COPD: Management Using Bronchodilators and Corticosteroids