The derivation of the spatial QRS-T angle and the spatial ventricular gradient using the Mason-Likar 12-lead
Daniel Guldenring1, Dewar D Finlay1, Raymond R Bond1
1Ulster University, Belfast, United Kingdom.
Abstract:
Research has shown that the 'spatial QRS-T angle' (SA) and the 'spatial ventricular gradient' (SVG) have clinical value in a number of different applications. The determination of the SA and the SVG requires vectorcardiographic data. Such data is seldom recorded in clinical practice. The SA and the SVG are therefore frequently derived from 12-lead electrocardiogram (ECG) data using linear lead transformation matrices. This research compares the performance of two previously published linear lead transformation matrices (Kors and ML2VCG) in deriving the SA and the SVG from Mason-Likar (ML) 12-lead ECG data. This comparison was performed through an analysis of the estimation errors that are made when deriving the SA and the SVG for all 181 subjects in the study population. The estimation errors were quantified as the systematic error (mean difference) and the random error (span of the Bland-Altman 95% limits of agreement). The random error was found to be the dominating error component for both the Kors and the ML2VCG matrix. The random error [ML2VCG; Kors; result of the paired, two-sided Pitman-Morgan test for statistical significance of differences in the error variance between ML2VCG and Kors] for the vectorcardiographic parameters SA, magnitude of the SVG, elevation of the SVG and azimuth of the SVG were found to be [37.33°; 50.52°; p<0.001], [30.17mVms; 39.09mVms; p<0.001], [36.77°; 47.62°; p=0.001] and [63.45°; 80.32°; p<0.001] respectively. The findings of this research indicate that in comparison to the Kors matrix the ML2VCG provides greater precision for estimating the SA and SVG from ML 12-lead ECG data.
More Related Videos
10:17Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
Related Concept Videos
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage....
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
ECG Interpretation of Arrhythmias I: Sinus Arrhythmias
Types of Arrhythmias
Sinus Node Arrhythmias
Sinus Bradycardia: Originating from the sinoatrial (SA) node, sinus bradycardia involves slower impulses, resulting in a heart rate of less than 60 beats per minute (bpm). Causes include sleep, vagal stimulation, beta-blockers, hypothyroidism,...
