Jove
Visualize
Contact Us

Related Concept Videos

Focusing of Light in the Eye01:16

Focusing of Light in the Eye

7.5K
Light rays enter the eye through the cornea, a transparent dome-shaped tissue that is the eye's outermost layer. The cornea bends or refracts, light rays traveling to the pupil. The shape of the cornea determines how much of the light is bent and whether the image will be focused correctly on the retina at the back of the eye. Once the light has passed through both refraction layers, it converges into a single focal point onto a small area. This is where photoreceptors start transforming...
7.5K
Spin–Spin Coupling Constant: Overview01:08

Spin–Spin Coupling Constant: Overview

1.6K
In bromoethane, the three methyl protons are coupled to the two methylene protons that are three bonds away. In accordance with the n+1 rule, the signal from the methyl protons is split into three peaks with 1:2:1 relative intensities. The methylene protons appear as a quartet, with the relative intensities of 1:3:3:1.
Qualitatively, any spin plus-half nucleus polarizes the spins of its electrons to the minus-half state. Consequently, the paired electron in the hydrogen–carbon bond must...
1.6K
Mechanism of Ciliary Motion01:05

Mechanism of Ciliary Motion

5.8K
The ciliary structures were first seen in 1647 by Antonie Leeuwenhoek while observing the protozoans. In lower organisms, these appendages are responsible for cell movement, while in higher organisms, these appendages help in the movement of the extracellular fluids within the body cavities.
The cilia are made up of microtubules in a 9+2 arrangement, with nine microtubule doublet ring bundles, surrounding a pair of central singlet microtubule bundles. The doublet microtubule bundles are...
5.8K
Mechanism of Ciliary Motion01:05

Mechanism of Ciliary Motion

2.7K
2.7K
Imaging Biological Samples with Optical Microscopy01:18

Imaging Biological Samples with Optical Microscopy

12.2K
Optical microscopy uses optic principles to provide detailed images of samples. Antonie van Leeuwenhoek designed the first compound optical microscope in the 17th century to visualize blood cells, bacteria, and yeast cells. In 1830, Joseph Jackson Lister created an essentially modern light microscope. The 20th century saw the development of microscopes with enhanced magnification and resolution.
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
12.2K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Sorbitol-Based Glass Matrices Enable Dynamic Nuclear Polarization beyond 200 K.

The journal of physical chemistry letters·2024
Same author

MAS-DNP enables NMR studies of insect wings.

Solid state nuclear magnetic resonance·2022
Same author

Psychoactive plant- and mushroom-associated alkaloids from two behavior modifying cicada pathogens.

Fungal ecology·2019
Same author

RF field strength control and an envelope detector.

Magnetic resonance in chemistry : MRC·2019
Same author

Description of an rf field-strength controller for solid-state NMR experiments.

Solid state nuclear magnetic resonance·2018
Same author

Solid-State NMR Study of the Cicada Wing.

The journal of physical chemistry. B·2017
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Video

Updated: Apr 3, 2026

Scanning Light Scattering Profiler SLPS Based Methodology to Quantitatively Evaluate Forward and Backward Light Scattering from Intraocular Lenses
06:55

Scanning Light Scattering Profiler SLPS Based Methodology to Quantitatively Evaluate Forward and Backward Light Scattering from Intraocular Lenses

Published on: June 6, 2017

8.0K

Adding a lens Improves spinning speed characterization.

Eugene Mihaliuk1, Terry Gullion1

  • 1West Virginia University, Morgantown, WV 26506, United States.

Solid State Nuclear Magnetic Resonance
|September 19, 2015
PubMed
Summary

Stable sample rotation is crucial for solid-state NMR. Adding a lens to the tachometer significantly reduces phase noise, enabling precise measurement of instantaneous spinning speed.

Keywords:
MAS NMRSpinning speed control

More Related Videos

Simulating the Mechanics of Lens Accommodation via a Manual Lens Stretcher
05:14

Simulating the Mechanics of Lens Accommodation via a Manual Lens Stretcher

Published on: February 23, 2018

7.3K
Application of High-speed Super-resolution SPEED Microscopy in Live Primary Cilium
07:53

Application of High-speed Super-resolution SPEED Microscopy in Live Primary Cilium

Published on: January 16, 2018

8.8K

Related Experiment Videos

Last Updated: Apr 3, 2026

Scanning Light Scattering Profiler SLPS Based Methodology to Quantitatively Evaluate Forward and Backward Light Scattering from Intraocular Lenses
06:55

Scanning Light Scattering Profiler SLPS Based Methodology to Quantitatively Evaluate Forward and Backward Light Scattering from Intraocular Lenses

Published on: June 6, 2017

8.0K
Simulating the Mechanics of Lens Accommodation via a Manual Lens Stretcher
05:14

Simulating the Mechanics of Lens Accommodation via a Manual Lens Stretcher

Published on: February 23, 2018

7.3K
Application of High-speed Super-resolution SPEED Microscopy in Live Primary Cilium
07:53

Application of High-speed Super-resolution SPEED Microscopy in Live Primary Cilium

Published on: January 16, 2018

8.8K

Area of Science:

  • Spectroscopy
  • Nuclear Magnetic Resonance (NMR)

Background:

  • Stable sample rotation is critical for high-quality solid-state NMR experiments.
  • Current methods for measuring spinning speed lack precision due to phase noise, hindering accurate assessment of rotation stability.

Purpose of the Study:

  • To investigate a simple method for improving the precision of sample rotation speed measurements in solid-state NMR.
  • To reduce phase noise in tachometer readings for more accurate real-time speed monitoring.

Main Methods:

  • Implemented a lens modification to the existing tachometer setup within a solid-state NMR probe.
  • Analyzed the impact of the lens on phase noise and the resulting precision of spinning speed measurements.

Main Results:

  • The addition of a lens reduced tachometer phase noise by nearly an order of magnitude.
  • This enhancement allowed for more rapid and precise measurements of the instantaneous sample rotation frequency.

Conclusions:

  • A simple lens addition to the tachometer is an effective method to improve solid-state NMR spinning speed measurement.
  • This technique enhances the ability to verify and achieve highly stable sample rotation, crucial for advanced NMR applications.