Impact of dynamic rate coding aspects of mobile phone networks on forensic voice comparison

Esam A S Alzqhoul1, Balamurali B T Nair1, Bernard J Guillemin1

  • 1Forensic and Biometrics Research Group (FaB); Department of Electrical and Computer Engineering, The University of Auckland, Private Bag 92019, Auckland Mail Centre, Auckland 1142, New Zealand.

Related Concept Videos

Design Example01:23

Design Example

The innovation of touch-tone telephony revolutionized the telecommunications industry by replacing the traditional rotary dial with a dual-tone multi-frequency (DTMF) signaling system. This system uses a matrix-style keypad with buttons arranged in four rows and three columns, creating 12 distinct signals each assigned to a pair of frequencies. Each button press results in a simultaneous generation of two sinusoidal tones – one from a low-frequency group (697 to 941 Hz) and one from a...
642
Doppler Effect - II01:05

Doppler Effect - II

The Doppler effect has several practical, real-world applications. For instance, meteorologists use Doppler radars to interpret weather events based on the Doppler effect. Typically, a transmitter emits radio waves at a specific frequency toward the sky from a weather station. The radio waves bounce off the clouds and precipitation and travel back to the weather station. The radio frequency of the waves reflected back to the station appears to decrease if the clouds or precipitation are moving...
5.1K
Difference from Background: Limit of Detection01:05

Difference from Background: Limit of Detection

The limit of detection (LOD) is the smallest amount of analyte that can be distinguished from the background noise. The LOD value corresponds to the concentration at which the analyte signal is three times larger than the standard deviation of the blank signal. Below this value, the analyte signal cannot be differentiated from the background noise. It is calculated by dividing the calibration slope by 3 times the standard deviation of the blank signals.
The LOD indicates the presence or absence...
9.1K
Drug Concentration Versus Time Correlation01:15

Drug Concentration Versus Time Correlation

The plasma drug concentration-time curve is a crucial tool in pharmacokinetics, representing the drug's concentration in plasma at different time intervals post-administration. This curve illustrates the drug's journey from absorption into the systemic circulation, distribution to body tissues, and eventual elimination through excretion or biotransformation.
Two pivotal parameters are the minimum effective concentration (MEC) and the minimum toxic concentration (MTC). The MEC is the...
2.8K
Aliasing01:18

Aliasing

Accurate signal sampling and reconstruction are crucial in various signal-processing applications. A time-domain signal's spectrum can be revealed using its Fourier transform. When this signal is sampled at a specific frequency, it results in multiple scaled replicas of the original spectrum in the frequency domain. The spacing of these replicas is determined by the sampling frequency.
If the sampling frequency is below the Nyquist rate, these replicas overlap, preventing the original...
811
Effects of EDTA on End-Point Detection Methods01:18

Effects of EDTA on End-Point Detection Methods

Different methods, such as visual observance of metal-ion indicators, spectroscopic techniques, and potentiometric methods, can determine the endpoint of an EDTA titration.
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
761