Related Experiment Video
Updated: Apr 3, 2026

Assessing Binocular Central Visual Field and Binocular Eye Movements in a Dichoptic Viewing Condition
Published on: July 21, 2020
A Modified Protocol for Color Vision Screening Using Ishihara
1UK Civil Aviation Authority, West Sussex, UK.
The Ishihara test is used to screen for color vision deficiencies, especially in occupational settings. However, some people with normal color vision may fail due to test design or unfamiliarity. This leads to unnecessary follow-up testing. The study tested two changes to the test protocol. One allowed a second attempt for minor errors. The other involved rotating the test plates. These changes reduced the false positive rate from up to 50% to 5.9%. The rotated plates did not affect correct identification. The authors suggest these modifications improve test fairness and reduce unnecessary testing. The findings are specific to the test conditions described in the study.
Area of Science:
- Medical diagnostics
- Visual perception research
- Occupational health screening
Background:
Color vision screening is a routine part of medical and occupational evaluations. The Ishihara test is widely used to detect red-green color deficiencies. However, some individuals with normal color vision may fail the test due to unfamiliarity or test design. This leads to unnecessary follow-up testing. The European Aviation Safety Agency requires stricter standards than the original Ishihara guidelines. These changes increase the false positive rate significantly. No prior work had resolved this issue effectively. This gap motivated the investigation of protocol modifications. The goal was to reduce false positives without compromising test accuracy.
Purpose Of The Study:
This study aimed to evaluate two changes to the Ishihara test protocol. The first modification allowed a second attempt for minor errors. The second involved rotating the test plates. The researchers wanted to determine if these changes could lower the false positive rate. They also sought to maintain the test’s ability to detect true color deficiencies. The motivation came from the high false positive rate reported under current standards. Reducing unnecessary advanced testing was a key objective. The study focused on occupational screening requirements. The findings could improve the reliability of initial color vision assessments.
Main Methods:
The study tested two protocol modifications. The first allowed a second attempt for minor errors. The second involved rotating the Ishihara plates. Researchers compared the false positive rates before and after these changes. They used a sample of subjects with normal color vision. The test conditions followed EASA guidelines. Plate rotation was applied to specific Ishihara plates. Error rates were recorded for each condition. The results were analyzed to assess the impact of the modifications.
Main Results:
The modified protocol reduced the false positive rate to 5.9%. This is a significant decrease from the previously reported 50%. The second attempt modification had the most impact. Rotated plates did not affect correct identification rates. These findings suggest the changes improve test accuracy. The results were consistent across all test conditions. No significant differences were found between rotated and standard plates. The study supports the use of these modifications in occupational screening.
Conclusions:
The authors propose that the modified Ishihara protocol reduces false positives. They suggest that allowing a second attempt improves test fairness. Rotating plates maintains diagnostic accuracy. The changes align with EASA requirements. The study supports the use of these modifications in practice. These adjustments may reduce unnecessary follow-up testing. The findings are specific to the test conditions described. The authors do not claim broader generalizations.
Frequently Asked Questions
The modified protocol reduced the false positive rate to 5.9% from up to 50%.
Plate rotation did not affect correct identification rates in the study.
To reduce false positives without compromising test accuracy.
It reduces unnecessary advanced testing for color vision.
Two modifications were tested: second attempt and plate rotation.
They propose it improves reliability without affecting diagnostic accuracy.
More Related Videos
05:10Author Spotlight: An Automated Method for Assessing Visual Acuity in Infants and Toddlers Using an Eye-Tracking System
Published on: March 17, 2023
12:23Dynamic Visual Tests to Identify and Quantify Visual Damage and Repair Following Demyelination in Optic Neuritis Patients
Published on: April 14, 2014
Related Concept Videos
Color Vision
Photoreceptors and Visual Pathways