Related Experiment Video
Updated: Apr 3, 2026

Development and Functionalization of Electrolyte-Gated Graphene Field-Effect Transistor for Biomarker Detection
Published on: February 1, 2022
A disposable chronocoulometric sensor for heavy metal ions using a diaminoterthiophene-modified electrode doped with
Seung-Min Choi1, Dong-Min Kim1, Ok-Sang Jung1
1Department of Chemistry and Institute of BioPhysio Sensor Technology, Pusan National University, Busan 609-735, South Korea.
Abstract:
The rapid simultaneous determination of cadmium, lead, copper, and mercury ions is performed by employing a disposable sensor modified with graphene oxide (GO) doped diaminoterthiophene (GO/DTT) for chronocoulometry (CC). The performances of CC with and without pre-deposition in two opposite potential step directions were compared with square wave anodic stripping voltammetry (SWASV) under various conditions. The surface of the GO/DTT modified screen print carbon electrode (SPCE) was characterized by SEM, EDXS, and electrochemical impedance spectroscopy (EIS). Experimental variables that affect the response signal such as the pH, deposition time, type of supporting electrolyte, concentration of DTT, content ratio of GO to DTT, and Nafion content were optimized. Interference effects due to other heavy metal ions were also investigated. The dynamic ranges of SWASV and CC were between 1 ng mL(-1) and 2.5 μg mL(-1) and between 1 ng mL(-1) and 10 μg mL(-1), respectively. The detection limits for Cd(2+), Pb(2+), Cu(2+), Hg(2+) ions were 1.9 ± 0.4 ng mL(-1), 2.8 ± 0.6 ng mL(-1), 0.8 ± 0.2 ng mL(-1), and 2.6 ± 0.9 ng mL(-1) for the CC stripping method; 2.6 ± 0.2 ng mL(-1), 0.5 ± 0.1 ng mL(-1), 1.8 ± 0.3 ng mL(-1), and 3.2 ± 0.3 ng mL(-1) for the CC deposition method; and 7.1 ± 0.9, 1.9 ± 0.3, 0.4 ± 0.1, and 0.7 ± 0.1 ng mL(-1) for SWASV. The reliability of the method for point-of-analysis was evaluated by analyzing a urine standard reference material and some water samples.
More Related Videos
09:15Iridium Oxide-reduced Graphene Oxide Nanohybrid Thin Film Modified Screen-printed Electrodes as Disposable Electrochemical Paper Microfluidic pH Sensors
Published on: November 22, 2016
11:18Manufacturing of a Nafion-coated, Reduced Graphene Oxide/Polyaniline Chemiresistive Sensor to Monitor pH in Real-time During Microbial Fermentation
Published on: January 7, 2019
Related Concept Videos
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Electrodeposition
Electrodeposition can...