Related Experiment Video
Updated: Apr 3, 2026

Chemiluminescence-based Assays for Detection of Nitric Oxide and its Derivatives from Autoxidation and Nitrosated Compounds
Published on: February 16, 2022
A ratiometric chemodosimeter for highly selective naked-eye and fluorogenic detection of cyanide
Wei-Chi Lin1, Jiun-Wei Hu1, Kew-Yu Chen1
1Department of Chemical Engineering, Feng Chia University, 40724 Taichung, Taiwan, ROC.
Abstract:
A simple indole-based chemosensor (1) with a very low molecular weight of 207 g mol(-1) has been synthesized for the highly reactive and selective detection of CN(-) in aqueous media, even in the presence of other anions, such as F(-), Cl(-), Br(-), AcO(-), [Formula: see text] , SCN(-), [Formula: see text] , [Formula: see text] , [Formula: see text] , BzO(-), [Formula: see text] , and [Formula: see text] . The sensor achieves rapid detection of cyanide anion in 2 min, and the pseudo-first-order rate constant is estimated as 1.576 min(-1). The colorimetric and ratiometric fluorescent response of the sensor to CN(-) is attributable to the addition of CN(-) to the electron-deficient dicyanovinyl group of 1, which prevents intramolecular charge transfer. The sensing mechanism is supported by density functional theory and time-dependent density functional theory calculations. Moreover, sensor 1 exhibits both high accuracy in determining the concentration of CN(-) in real samples and 1-based test strips can conveniently detect CN(-) without any additional equipment. The detection limit of the sensor 1 (1.1 μM) for cyanide is lower than the maximum permissible level of CN(-) (1.9 μM) in drinking water.
More Related Videos
08:25Measuring Nitrite and Nitrate, Metabolites in the Nitric Oxide Pathway, in Biological Materials using the Chemiluminescence Method
Published on: December 25, 2016
10:57Experimental Protocol for Detecting Cyanobacteria in Liquid and Solid Samples with an Antibody Microarray Chip
Published on: February 7, 2017
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Redox Titration: Overview
High-Performance Liquid Chromatography: Types of Detectors