Related Experiment Video
Updated: Apr 3, 2026

Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
A novel technique to prevent guide wire related complications while inserting the 4.0 mm cannulated screws
Bao-Chang Qi1, Wei-Na Ju2, Tie-Jun Wang1
1The Division of Orthopedic Traumatology, The First Hospital of Jilin University, Changchun, Jilin, China.
Background:
Cannulated screws (4.0 mm) provide inter-fragmentary compression and stability to fractures. A guide wire is used to define the screw trajectory and hold the fracture fragment while the screw is being inserted. The cannulated shaft typically accommodates a 1.25 mm guide pin. Since the guide pin is very slender and undergoes elastic deformation during insertion, there is a high probability of pin breakage.
Methods:
The authors have devised a new way to place the 4.0 mm cannulated screws in a manner that prevents the intraoperative complication of guide wire breakage. For this technique, predrilling was achieved using a 2.0 mm K-wire which was subsequently replaced with a 1.25 mm guide pin under the protection of sleeve. 4.0 mm cannulated screws were then inserted into a defined trajectory over the guide pin.
Results:
Using the technique, over 20 patients were managed in our department over a period of two years without any complications.
Conclusion:
We have observed that patients treated with this method experience short operation time, combined with good clinical outcome and we recommend its use in cases where cannulated screw use is warranted.