Problems and expediencies in human 31P spectroscopy. The definition of localized volumes, dealing with saturation and the technique-dependence of quantification
Related Experiment Video
Updated: Oct 11, 2026

Metabolomic Analysis of Rat Brain by High Resolution Nuclear Magnetic Resonance Spectroscopy of Tissue Extracts
Published on: September 21, 2014
P A Bottomley1, C J Hardy, P B Roemer
1General Electric Corporate Research and Development Center, Schenectady, New York 12301.
Abstract:
Several technological problems in in vivo localized spectroscopy of metabolism are discussed in the context of comparing data obtained by different means. Deficiencies in spectroscopy localization methods can produce spectra that are dominated by artefactual signals derived from outside of selected volumes. Such artefacts are not usually correctly accounted for by representations of the profiles of the transverse magnetization alone. Selected sensitive volumes should be defined in terms of the size of tissue contributing the major fraction of signal to an observed spectrum, which is the integrated response from the sample including any phase cancellation effects. Phase cancellation in one-dimensional localization techniques employing excitation by an RF field with uniform phase distribution and surface coil detection such as depth resolved surface coil spectroscopy, chemical shift imaging (CSI) and rotating frame zeugmatography (RFZ) can significantly alter the effective radius of the sensitive volumes depending on the sample distribution and the extent of the homogeneous region of the magnet. Also, discrete spatial sampling in RFZ and CSI can radiate signal artefacts of around 25% into adjacent elements depending on the location and distribution of signal sources. Acquisition delays between excitation and detection and partial saturation are other major sources of systematic error. Saturation factors for metabolites are not easily obtainable on localized volumes during clinical exams on an individual basis, but may be expediently obtained as larger-volume tissue-averages. Better documentation of saturation effects, acquisition delays and localized volume sizes is needed to compare and validate clinical results and performance.
Related Concept Videos
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)
Two-Dimensional (2D) NMR: Overview
The first step is the preparation period, during which nucleus A is excited with a radiofrequency pulse.
NMR Spectrometers: Resolution and Error Correction
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences
2D NMR: Overview of Homonuclear Correlation Techniques
COSY90 is the standard two-dimensional (2D) COSY experiment that...