Related Experiment Video
Updated: Apr 1, 2026

Anogenital Distance and Perineal Measurements of the Pelvic Organ Prolapse POP Quantification System
Published on: September 20, 2018
Digital assessment and quantification of pelvic organ prolapse (DPOP-Q): a randomised cross-over diagnostic agreement
Ganesh Thiagamoorthy1, Martino Zacchè2, Linda Cardozo2
1King's College Hospital, London, SE5 9RS, UK. gans.t@nhs.net.
Introduction:
Pelvic Organ Prolapse Quantification (POP-Q) system, measured in centimetres using a ruler (e.g. POPstix®), is recommended to quantify prolapse severity. POPstix® are costly (US $1/ruler). Home-made devices are used instead, but these have not been shown to be reproducible.
Hypothesis:
Digitally assessed POP-Q (DPOP-Q) is as reliable, reproducible and acceptable as POP-Q assessed using POPstix®.
Methods:
In this randomised crossover diagnostic agreement trial, each assessor measured the index finger of their dominant hand using a ruler. At visit one, patients were randomised to either POPstix® POP-Q assessment in a modified lithotomy position or DPOP-Q in both modified a lithotomy and a standing position. After the first clinician conducted this assessment, a second blinded clinician then carried out the remaining assessment on the same patient. For each examination, duration was recorded, along with a patient-completed discomfort score. Twenty-five women were invited for visit two, at which DPOP-Q was recorded by the same clinician who undertook DPOP-Q at the first visit. This allowed evaluation of inter- and intraobserver agreement together with examination acceptability.
Results:
One hundred and nine women were recruited [median age 55 years, parity 2, body mass index (BMI) 27.1]. Of the 25 patients invited, 23 returned for visit two. DPOP-Q had high interobserver reliability [κ = 0.94, 95 % confidence interval (CI) 0.878-0.996] and intraobserver reliability (α = 0.96) with POPstix®. DPOP-Q was significantly quicker (p = 0.02) and less uncomfortable (p < 0.01) than POPstix® POP-Q.
Conclusion:
DPOP-Q is reliable, acceptable and cost effective.
More Related Videos
07:41Quantification of Levator Ani Hiatus Enlargement by Magnetic Resonance Imaging in Males and Females with Pelvic Organ Prolapse
Published on: April 17, 2019
03:30Author Spotlight: Advancing Pelvic Prolapse Treatment with a Non-Mesh Approach using Laparoscopic Pectopexy
Published on: October 25, 2024
Related Concept Videos
Imaging Studies VI: Voiding Cystourethrography and Cystography
Assessment of the Rectum and Anus
Rectal Inspection
Begin by inspecting the perianal and anal areas for color, texture, rashes,...
Assessment of the Abdomen III: Palpation
Assessment of the Abdomen II: Percussion
Percussion
Percussion is an essential...