Occupational Exposure to Veterinary Workers from the Positron Emission Tomography Imaging Agent 64Cu-ATSM
Lucas D Hetrick1, Susan L Kraft, Thomas E Johnson
1*Colorado State University, Department of Environment and Radiological Health Sciences, Fort Collins, Co.
Abstract:
Cu-ATSM is an emerging radiopharmaceutical for diagnostic use in positron emission tomography (PET), but to date there are no studies that assess the potential occupational doses to workers in either human or veterinary medicine. This study was aimed at determining the external radiation dose to veterinary workers from clinical PET/CT (PET combined with computed tomography) procedures using Cu-ATSM. To determine the dose to the workers, each worker was assigned two Electronic Personal Dosimeters (EPDs) to be worn on the chest and waist during the entirety of each procedure. The workers monitored during this study included a radiobiologist, a nuclear medicine technologist, an anesthesiologist, and a veterinary surgeon. Seven canine patients were imaged with an average mass of 33.7 kg (a range of 20.0-55.1 kg) with an average injected activity of 5 MBq kg. The dose range for the radiobiologist was 2-17 μSv (mean of 7.1 μSv), for the nuclear medicine technologist 0-14 μSv (mean of 5.6 μSv), for the anesthesiologist 0-12 μSv (mean of 4.0 μSv), and for the surgeon 0-10 μSv (mean of 3.6 μSv). In a comparison between the results of this study and published literature on occupational exposures from veterinary FDG PET/CT procedures, Cu-ATSM veterinary PET/CT procedures, on a per patient bias, exposed workers to less radiation.
More Related Videos
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...