Assessment of carboxyhemoglobin, hydrogen cyanide and methemoglobin in fire victims: a novel approach
Related Experiment Video
Updated: Apr 1, 2026

A Rapid and Chemical-free Hemoglobin Assay with Photothermal Angular Light Scattering
Published on: December 7, 2016
Luis A Ferrari1, Leda Giannuzzi2
1Cátedra Toxicología y Química Forense, Facultad de Ciencias Exactas y Derecho, U.M, Cabildo 134, 1708 Morón, Buenos Aires, Argentina.
To establish the cause of death, carboxyhemoglobin (COHb), total hemoglobin (tHb), methemoglobin (MetHb), and hydrogen cyanide (HCN) were quantified in the blood of fire victims. We analyzed 32 out of 33 blood samples from forensic autopsy cases in a disastrous polyurethane mattress fire, which caused the deaths of 33 inmates at a prison in Argentina in 2006. The cadaveric blood samples were collected by femoral vein puncture. These samples were analyzed using the IL80 CO-oximeter system for tHb, MetHb, and COHb levels and by microdiffusion for HCN and COHb levels. Blood alcohol (ethanol) and drugs were examined by headspace gas chromatography-flame ionization detection (HS-GC-FID) and GC-mass spectrometry (MS), respectively. Polyurethane mattress samples were analyzed according to the California 117 protocol. The saturation of COHb ranged from 10% to 43%, tHb from 2% to 19.7%, MetHb from 0.10% to 35.7%, and HCN from 0.24 to 15mg/L. These HCN values are higher than the lethal levels reported in the literature. Other toxic components routinely measured (ethanol, methanol, aldehydes, and other volatile compounds) gave negative results in the 32 cases. Neither drugs of abuse nor psychotropic drugs were detected. The results indicate that death in the 32 fire victims was probably caused in part by HCN, generated during the extensive polyurethane decomposition stimulated by a rapid increase in temperature. We also considered the influence of oxygen depletion and the formation of other volatile compounds such as NOx in this disaster, as well as pathological evidence demonstrating that heat was not the cause of death in all victims. Furthermore, statistical analysis showed that the percentage values of COHb and MetHb in the blood were not independent variables, with χ(2)=11.12 (theoretical χ(2)=4.09, degrees of freedom=12, and α=0.05). However, no correlation was found between HCN and MetHb in the blood of the victims. This is the first report to assess the relationship between COHb and MetHb in forensic blood samples. We further discuss other factors that could lead to a lethal atmosphere generated by the fire and compare the data from this disaster with that of other published fire episodes.
To establish the cause of death, carboxyhemoglobin (COHb), total hemoglobin (tHb), methemoglobin (MetHb), and hydrogen cyanide (HCN) were quantified in the blood of fire victims. We analyzed 32 out of 33 blood samples from forensic autopsy cases in a disastrous polyurethane mattress fire, which caused the deaths of 33 inmates at a prison in Argentina in 2006. The cadaveric blood samples were collected by femoral vein puncture. These samples were analyzed using the IL80 CO-oximeter system for tHb, MetHb, and COHb levels and by microdiffusion for HCN and COHb levels. Blood alcohol (ethanol) and drugs were examined by headspace gas chromatography-flame ionization detection (HS-GC-FID) and GC-mass spectrometry (MS), respectively. Polyurethane mattress samples were analyzed according to the California 117 protocol. The saturation of COHb ranged from 10% to 43%, tHb from 2% to 19.7%, MetHb from 0.10% to 35.7%, and HCN from 0.24 to 15mg/L. These HCN values are higher than the lethal levels reported in the literature. Other toxic components routinely measured (ethanol, methanol, aldehydes, and other volatile compounds) gave negative results in the 32 cases. Neither drugs of abuse nor psychotropic drugs were detected. The results indicate that death in the 32 fire victims was probably caused in part by HCN, generated during the extensive polyurethane decomposition stimulated by a rapid increase in temperature. We also considered the influence of oxygen depletion and the formation of other volatile compounds such as NOx in this disaster, as well as pathological evidence demonstrating that heat was not the cause of death in all victims. Furthermore, statistical analysis showed that the percentage values of COHb and MetHb in the blood were not independent variables, with χ(2)=11.12 (theoretical χ(2)=4.09, degrees of freedom=12, and α=0.05). However, no correlation was found between HCN and MetHb in the blood of the victims. This is the first report to assess the relationship between COHb and MetHb in forensic blood samples. We further discuss other factors that could lead to a lethal atmosphere generated by the fire and compare the data from this disaster with that of other published fire episodes.
More Related Videos
08:51Intra-cardiac Side-Firing Light Catheter for Monitoring Cellular Metabolism using Transmural Absorbance Spectroscopy of Perfused Mammalian Hearts
Published on: May 12, 2019
08:23Chemiluminescence-based Assays for Detection of Nitric Oxide and its Derivatives from Autoxidation and Nitrosated Compounds
Published on: February 16, 2022
Related Concept Videos
Hypoxia
Types of Hypoxia
There are four primary types of hypoxia, each resulting from a different cause:
1. Anemic hypoxia: This type occurs due to insufficient oxygen delivery caused by a lack of red blood cells (RBCs) or RBCs with abnormal or...
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Blood Studies for Cardiovascular System I: Cardiac Biomarkers
The essential diagnostic tools for detecting myocardial necrosis and monitoring individuals suspected of having acute coronary syndrome (ACS) include:
Troponins
Troponins, particularly cardiac troponins I and T, are the most precise and sensitive markers of myocardial injury. They are detectable within 4-6 hours of myocardial injury and remain...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Hemoglobin
When all four heme groups are bound to oxygen, the resulting molecule is called oxyhemoglobin. As a result, arterial blood...