Longitudinal Trend in Lipid Profile of Incident Peritoneal Dialysis Patients is Not Influenced by the Use of
Yeoungjee Cho1, Janine Büchel2, Sonja Steppan2
1Department of Renal Medicine, Princess Alexandra Hospital, Brisbane, Australia School of Medicine, University of Queensland, Brisbane, Australia Translational Research Institute, Brisbane, Australia.
Unlabelled:
♦
Background:
The longitudinal trends of lipid parameters and the impact of biocompatible peritoneal dialysis (PD) solutions on these levels remain to be fully defined. The present study aimed to a) evaluate the influence of neutral pH, low glucose degradation product (GDP) PD solutions on serum lipid parameters, and b) explore the capacity of lipid parameters (total cholesterol [TC], triglyceride [TG], high density lipoprotein [HDL], TC/HDL, low density lipoprotein [LDL], very low density lipoprotein [VLDL]) to predict cardiovascular events (CVE) and mortality in PD patients. ♦
Methods:
The study included 175 incident participants from the balANZ trial with at least 1 stored serum sample. A composite CVE score was used as a primary clinical outcome measure. Multilevel linear regression and Poisson regression models were fitted to describe the trend of lipid parameters over time and its ability to predict composite CVE, respectively. ♦
Results:
Small but statistically significant increases in serum TG (coefficient 0.006, p < 0.001), TC/HDL (coefficient 0.004, p = 0.001), and VLDL cholesterol (coefficient 0.005, p = 0.001) levels and a decrease in the serum HDL cholesterol levels (coefficient -0.004, p = 0.009) were observed with longer time on PD, whilst the type of PD solution (biocompatible vs standard) received had no significant effect on these levels. Peritoneal dialysis glucose exposure was significantly associated with trends in TG, TC/HDL, HDL and VLDL levels. Baseline lipid parameter levels were not predictive of composite CVEs or all-cause mortality. ♦
Conclusion:
Serum TG, TC/HDL, and VLDL levels increased and the serum HDL levels decreased with increasing PD duration. None of the lipid parameters were significantly modified by biocompatible PD solution use over the time period studied or predictive of composite CVE or mortality.
Related Concept Videos
Peritoneal Dialysis I: Introduction and Procedure
Peritoneal Dialysis II: Peritoneal Dialysis Systems and Complications
Peritoneal Dialysis III: Nursing Management
Dialysis
Dialysis
Acute kidney injury develops suddenly and can be caused by pre-renal causes (e.g., hypovolemia, shock), intrinsic renal causes (e.g., acute tubular necrosis), or post-renal causes (e.g., urinary obstruction). In contrast, chronic renal failure progresses gradually over time and is often...
Hemodialysis III: Nursing Management