Related Experiment Video
Updated: Apr 1, 2026

Author Spotlight: Advancing Awake Nasotracheal Intubation with Flexible Video Rhino-Laryngoscopes
Published on: August 2, 2024
Better Hemodynamic Profile of Laryngeal Mask Airway Insertion Compared to Laryngoscopy and Tracheal Intubation
Hashem Jarineshin1, Saeed Kashani1, Majid Vatankhah1
1Anesthesiology, Critical Care and Pain Management Research Center, Hormozgan University of Medical Sciences, Bandar Abbas, IR Iran.
Background:
Laryngoscopy and tracheal intubation can cause serious cardiovascular responses in patients such as hypertension, tachycardia, and arrhythmias. Alternative airway maintenance techniques may attenuate these hemodynamic stress responses.
Objectives:
This study aimed to compare the immediate hemodynamic effects of the insertion of laryngeal mask airway supreme (LMA-S) and classic (LMA-C) with laryngoscopy and Endotracheal Intubation (ETT).
Patients And Methods:
This study was a prospective, double-blind, and randomized clinical trial conducted on 150 patients aged 18 to 50 years with ASA I (American Society of Anesthesiologists), in the general operating room of Shahid Mohammadi hospital, Hormozgan university of medical sciences, Bandar Abbas, Iran. In the ETT group, endotracheal intubation was performed using the Macintosh laryngoscope; while for the LMA-C and LMA-S groups, LMA Classic and LMA Supreme were inserted, respectively. The induction and maintenance of anesthesia were similar in all patients. The hemodynamic parameters such as heart rate (HR), systolic blood pressure (SBP), and diastolic blood pressure (DBP) were measured before (baseline) and after induction of anesthesia at 4 different time points. The statistical analysis was done and P value less than 0.05 was considered significant.
Results:
Participants in all groups were similar in terms of gender, age, weight, height, and Mallampati class. The mean ± SD of SBPs (105.62 ± 12.12, 112.90 ± 12.2, and 112.48 ± 15.14 mm Hg, respectively for ETT, LMA-C, and LMA-S) and DBPs (64.64 ± 10.23, 73.78 ± 9.70, and 71.20 ± 12.27 mm Hg, respectively for ETT, LMA-C, and LMA-S) were significantly lower in the ETT group compared to LMA groups 5 minutes after device insertion (P < 0.01 for SBPs and P < 0.001 for DBPs); however these values were lower than the baseline values in all groups. There were no differences in the mean SBP and DBPs between the three groups at the other time points. The mean ± SD heart rates in the ETT group, compared to the LMA-C and LMA-S groups, were considerably higher in the first minute (100.06 ± 18.27, 82.50 ± 10.52, and 82.00 ± 13.60 bpm, respectively for ETT, LMA-C, and LMA-S), third minute (91.04 ± 17.12, 78.84 ± 11.23, and 78.90 ± 13.41 bpm, respectively for ETT, LMA-C, and LMA-S) and fifth minute (85.82 ± 16.01, 75.78 ± 11.73, and 75.04 ± 13.90 bpm, respectively for ETT, LMA-C, and LMA-S) after intubation (P < 0.001). There were no significant differences between the LMA-C and LMA-S groups in terms of hemodynamic parameters.
Conclusions:
Maintaining the airway using laryngeal mask airway is associated with less cardiovascular responses compared to direct laryngoscopy and tracheal intubation.
Related Concept Videos
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Tracheostomy Suctioning I: Pre-Procedural Steps
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...