Related Experiment Video
Updated: Apr 1, 2026

Implantation and Control of Wireless, Battery-free Systems for Peripheral Nerve Interfacing
Published on: October 20, 2021
Primary side control of load voltage for transcutaneous energy transmission
Yang Fu1, Liang Hu2, Xiaodong Ruan1
1The State Key Laboratory of Fluid Power Transmission and Control, Zhejiang University, Zheda Road 38, Hangzhou, 310027, China.
Abstract:
Transcutaneous energy transmission (TET) is considered as a good way to wirelessly power the implanted devices in human bodies. The load voltage provided from the TET to the implanted device should be kept stable to ensure the device working well, which however, is easily affected by the required power variation for different body movements and coil-couple malposition accompanying skin peristalsis. Commonly, the load voltage applied onto the device should be measured and feedback for power is regulated by implanting sensing and communication units into the body, which causes additional energy cost, increased size and weight of the implanted device. This paper takes the TET for artificial heart as an example to propose a novel primary side control method of the load voltage for TET, which does not require any additional implanted components. In the method, sensing coils are used to measure the malposition between the transmitter coil (TC) and receiver coil, and the magnitude of the TC current outside the human body. The measurement results are used to estimate the load voltage inside the body through calculation, whose value provide a base to develop a PI control system to regulate the input power of TET for the load voltage stability. The proposed method is experimentally validated on an actual TET for artificial heart by varying its load in a wide range under serious coil-couple malposition. With applying the primary side control, the variation of the load voltage is reduced to only 25 % of that without the control.
More Related Videos
14:47Author Spotlight: Combined Peripheral Nerve Stimulation and Controllable Pulse Parameter Transcranial Magnetic Stimulation to Probe Sensorimotor Control and Learning
Published on: April 21, 2023
11:12Controlling Parkinson's Disease With Adaptive Deep Brain Stimulation
Published on: July 16, 2014
Related Concept Videos
Generator Voltage Control
Electrodes: Overview
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in...
Energy Supply for Muscle Contraction