Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Electron Microscope Tomography and Single-particle Reconstruction01:07

Electron Microscope Tomography and Single-particle Reconstruction

3.0K
Transmission electron microscopy (TEM) can be used to determine the 3D structure of biological samples with the help of techniques such as electron microscope tomography and single-particle reconstruction. While single-particle reconstruction can examine macromolecules and macromolecular complexes in vitro conditions only, tomography permits the study of cell components or small cells in vivo.
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
3.0K
Transmission Electron Microscopy01:15

Transmission Electron Microscopy

7.9K
In 1931, physicist Ernst Ruska—building on the idea that magnetic fields can direct an electron beam just as lenses can direct a beam of light in an optical microscope—developed the first prototype of the electron microscope. This development led to the development of the field of electron microscopy. In the transmission electron microscope (TEM), electrons are produced by a hot tungsten element and accelerated by a potential difference in an electron gun, which gives them up to 400...
7.9K
Scanning Electron Microscopy01:07

Scanning Electron Microscopy

6.0K
A scanning electron microscope (SEM) is used to study the surface features of a sample by using an electron beam that scans the sample surface in a two-dimensional manner. Typically, areas between ~1 centimeter to 5 micrometers in width can be imaged. SEM can be used to image bacteria, viruses, tissues as well as larger samples like insects. Conventional SEM gives a magnification ranging from 20X to 30,000X and spatial resolution of 50 to 100 nanometers.
Fundamental Principles
Accelerated...
6.0K
Overview of Electron Microscopy01:25

Overview of Electron Microscopy

16.5K
The wavelengths of visible light ultimately limit the maximum theoretical resolution of images created by light microscopes. Most light microscopes can only magnify 1000X, and a few can magnify up to 1500X. Electrons, like electromagnetic radiation, can behave like waves, but with wavelengths of 0.005 nm, they produce significantly greater resolution up to 0.05 nm as compared to 500 nm for visible light. An electron microscope (EM) can create a sharp image that is magnified up to 2,000,000X.
16.5K
Computed Tomography01:10

Computed Tomography

9.5K
Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
9.5K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Orbital magnetoresistance in the antiferromagnet CoO driven by dynamic orbital angular momentum.

Science (New York, N.Y.)·2026
Same author

Temperature-dependent mean inner potential of polystyrene spheres measured using off-axis electron holography.

Ultramicroscopy·2026
Same author

Towards reliable electrical measurements of superconducting devices inside a transmission electron microscope.

Ultramicroscopy·2026
Same author

Selective Narrowing of the Bonding Modes of Plasmonic Nanoantennas.

ACS applied materials & interfaces·2026
Same author

Atomic-scale quantification of individual oxygen vacancies and structural evolution in valence change memristors.

Nature communications·2026
Same author

Picosecond-scale coherent toggle switching of topological spin helicity.

Nature nanotechnology·2026
Same journal

Serum vitamin D level and its association with vertigo frequency and severity in Meniere disease.

Scientific reports·2026
Same journal

PFA-Net: a physics-informed feature enhancement and attention network for interpretable bearing fault diagnosis under strong noise.

Scientific reports·2026
Same journal

Circulating inflammatory, redox, and apoptosis-related alterations in drug-naive idiopathic pulmonary fibrosis: an exploratory case-control study.

Scientific reports·2026
Same journal

A baseline-oriented dynamic aggregation approach for demand-side heterogeneous controllable resources.

Scientific reports·2026
Same journal

Temporal precision and accuracy in schizophrenia: an exploratory study.

Scientific reports·2026
Same journal

Prefrontal EEG spectral and nonlinear signatures of subthreshold depression during resting state and affectively valenced picture/video viewing: a participant-level analysis.

Scientific reports·2026
See all related articles

Related Experiment Video

Updated: Apr 1, 2026

Imaging Replicative Domains in Ultrastructurally Preserved Chromatin by Electron Tomography
14:56

Imaging Replicative Domains in Ultrastructurally Preserved Chromatin by Electron Tomography

Published on: May 20, 2022

4.2K

Rapid low dose electron tomography using a direct electron detection camera.

Vadim Migunov1, Henning Ryll2, Xiaodong Zhuge3

  • 1Ernst Ruska-Centre for Microscopy and Spectroscopy with Electrons and Peter Grünberg Institute, Forschungszentrum Jülich, D-52425 Jülich, Germany.

Scientific Reports
|October 6, 2015
PubMed
Summary
This summary is machine-generated.

We achieved ultra-fast electron tomography, capturing 3487 images in 3.5 seconds. This method significantly reduces electron dose and enhances signal-to-noise for sensitive materials.

More Related Videos

User-friendly, High-throughput, and Fully Automated Data Acquisition Software for Single-particle Cryo-electron Microscopy
07:56

User-friendly, High-throughput, and Fully Automated Data Acquisition Software for Single-particle Cryo-electron Microscopy

Published on: July 29, 2021

4.1K
Cryo-Electron Tomography Remote Data Collection and Subtomogram Averaging
08:55

Cryo-Electron Tomography Remote Data Collection and Subtomogram Averaging

Published on: July 12, 2022

6.1K

Related Experiment Videos

Last Updated: Apr 1, 2026

Imaging Replicative Domains in Ultrastructurally Preserved Chromatin by Electron Tomography
14:56

Imaging Replicative Domains in Ultrastructurally Preserved Chromatin by Electron Tomography

Published on: May 20, 2022

4.2K
User-friendly, High-throughput, and Fully Automated Data Acquisition Software for Single-particle Cryo-electron Microscopy
07:56

User-friendly, High-throughput, and Fully Automated Data Acquisition Software for Single-particle Cryo-electron Microscopy

Published on: July 29, 2021

4.1K
Cryo-Electron Tomography Remote Data Collection and Subtomogram Averaging
08:55

Cryo-Electron Tomography Remote Data Collection and Subtomogram Averaging

Published on: July 12, 2022

6.1K

Area of Science:

  • Materials Science
  • Microscopy
  • Nanotechnology

Background:

  • Transmission electron microscopy (TEM) is crucial for nanoscale imaging.
  • Conventional electron tomography requires long acquisition times and high electron doses.
  • Electron-beam-sensitive specimens are challenging to image with high resolution.

Purpose of the Study:

  • To develop a rapid electron tomography method for sensitive specimens.
  • To improve signal-to-noise ratio in tomographic datasets.
  • To enable real-time dynamic electron tomography.

Main Methods:

  • Utilized a direct electron detector in a transmission electron microscope.
  • Recorded a tomographic tilt series of 3487 images in 3.5 seconds.
  • Achieved ultra-low electron dose imaging.

Main Results:

  • Acquisition of a large tilt series (3487 images) in 3.5 seconds.
  • Electron dose reduced by over an order of magnitude compared to conventional methods.
  • Signal-to-noise ratio greater than 4 achieved.
  • Demonstrated feasibility on an inorganic nanotube.

Conclusions:

  • This technique enables ultra-low-dose electron tomography for beam-sensitive samples.
  • Real-time dynamic electron tomography with sub-millisecond temporal resolution is now possible.
  • Opens new avenues for studying dynamic nanoscale processes.