Related Experiment Video
Updated: Apr 1, 2026

Surgical Robot-Assisted Transanal Specimen Extraction Radical Sigmoidectomy Without an Auxiliary Abdominal Incision
Published on: June 13, 2025
[Full thickness resection device (FTRD). Experience and outcome for benign neoplasms of the rectum and colon]
H-J Richter-Schrag1, C Walker2, R Thimme2
1Interdisziplinäre Gastrointestinale Endoskopie, Kliniken für Innere Medizin II, Universitätsklinik Freiburg, Sir Hans A. Krebs Strasse, 79106, Freiburg im Breisgau, Deutschland. hans-juergen.schrag@uniklinik-freiburg.de.
Background:
The diagnostic validity of a full-thickness resection is higher compared to endoscopic mucosal resection (EMR) or endoscopic mucosal dissection (ESD). Whereas transanal endoscopic microsurgery techniques (TEM, TAMIS) are established therapeutic procedures in the rectum no established and safe minimally invasive or endoscopic procedure exists in the colon.
Aim:
In this study the novel endoscopic full thickness resection device (FTRD, Ovesco, Germany) was investigated concerning success rates with histologically proven full thickness resections, R0 status as well as patient and device safety for the rectum and colon.
Method:
In the period from November 2014 to June 2015 full thickness resections in the rectum and colon were performed with the FTRD in 20 patients. Data on technical success, R0 resection rate and histologically confirmed full thickness resections were retrospectively analyzed.
Results:
The following indications were treated in the rectum (n = 11) and colon (n = 9): T1 carcinoma (n = 6) and neuroendocrine tumors (n = 2), untreated and nonlifting adenomas (n = 3) and incomplete resection of adenomas with low and high grade dysplasia (n = 9). The technical success rate was 75 %, 3 technical failures made a conventional polypectomy necessary in 2 patients and in 1 patient an operative resection of the duplicated intestinal wall had to be performed. The median endoscopic follow-up time was 61.5 days (n = 10) and in 7 patients the clip had dislodged at the first follow-up. A thermal perforation in one case of conventional polypectomy gave rise to indications for a partial resection of the colon. In one patient the lesion in the cecum could be reached but not treated for technical reasons. The histological R0 rate was 80 %, whereas the full thickness resection rate was 60 % (85.7 % in the colon and 54.6 % in the rectum). In two patients with carcinoma and incomplete FTRD, surgical treatment was performed. The median size of the resection specimen was 5 cm(2) (range 1.6-12.9 cm(2)).
Conclusion:
The results show that FTRD is a safe and effective instrument for use in the lower gastrointestinal tract. Limitations of the FTRD system concerning full thickness resection are scarring, fibrosis and thickness of the intestinal wall, especially in the lower rectum; therefore, it is suggested that a simulation with a tube similar in size to the FTRD should be performed during the screening colonoscopy in order to establish whether an endoscopic resection with FTRD is possible.
More Related Videos
04:09The Pocket-Creation Procedure of Endoscopic Submucosal Dissection for Large Rectal Laterally Spreading Tumors
Published on: February 13, 2026
12:45Robot-assisted Total Mesorectal Excision and Lateral Pelvic Lymph Node Dissection for Locally Advanced Middle-low Rectal Cancer
Published on: February 12, 2022
Related Concept Videos
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Inflammatory Bowel Disease V: Surgical Management
Here are some common surgical interventions for IBD:
Endoscopic Procedures II: Colonoscopy
Assessment of the Rectum and Anus
Rectal Inspection
Begin by inspecting the perianal and anal areas for color, texture, rashes,...