Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Phase Contrast and Differential Interference Contrast Microscopy01:26

Phase Contrast and Differential Interference Contrast Microscopy

15.2K
Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
15.2K
Computed Tomography01:10

Computed Tomography

9.5K
Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
9.5K
Imaging Studies III: Computed Tomography01:27

Imaging Studies III: Computed Tomography

677
DefinitionComputed Tomography (CT) of the genitourinary (GU) tract is a non-invasive imaging modality that utilizes X-rays and computer processing to generate detailed cross-sectional images of the urinary system, encompassing the kidneys, ureters, bladder, and adjacent structures such as the adrenal glands.PurposeCT scans of the GU tract serve several diagnostic and therapeutic purposes, including:Diagnosis of Urinary Tract Diseases: Detects kidney stones, tumors, cysts, and congenital...
677
Imaging Biological Samples with Optical Microscopy01:18

Imaging Biological Samples with Optical Microscopy

12.2K
Optical microscopy uses optic principles to provide detailed images of samples. Antonie van Leeuwenhoek designed the first compound optical microscope in the 17th century to visualize blood cells, bacteria, and yeast cells. In 1830, Joseph Jackson Lister created an essentially modern light microscope. The 20th century saw the development of microscopes with enhanced magnification and resolution.
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
12.2K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

OMEGA V2: GPU-accelerated Python and MATLAB software for PET, SPECT, and CT reconstruction.

Physics in medicine and biology·2026
Same author

Multi-resolution extended-volume model for iterative reconstruction in cone beam CT.

Physics in medicine and biology·2026
Same author

Branchless distance-driven and hybrid projectors in iterative cone beam CT.

Journal of X-ray science and technology·2026
Same author

Iterative Born solver for the acoustic Helmholtz equation with heterogeneous sound speed and density.

The Journal of the Acoustical Society of America·2026
Same author

Simulating light transmission and wavefront shaping in turbid media with a T-matrix method.

Optics express·2025
Same author

Non-stationary estimation of optical absorption in ultrasound-modulated diffuse optical tomography.

Journal of the Optical Society of America. A, Optics, image science, and vision·2025

Related Experiment Video

Updated: Apr 1, 2026

Computed Tomography-guided Time-domain Diffuse Fluorescence Tomography in Small Animals for Localization of Cancer Biomarkers
12:24

Computed Tomography-guided Time-domain Diffuse Fluorescence Tomography in Small Animals for Localization of Cancer Biomarkers

Published on: July 17, 2012

13.0K

Nonlinear approach to difference imaging in diffuse optical tomography.

Meghdoot Mozumder1, Tanja Tarvainen2, Aku Seppänen1

  • 1University of Eastern Finland, Department of Applied Physics, P.O. Box 1627, Kuopio 70211, Finland.

Journal of Biomedical Optics
|October 7, 2015
PubMed
Summary
This summary is machine-generated.

This study introduces a novel nonlinear approach for difference imaging, improving quantitative accuracy and spatial resolution over traditional linear methods. The nonlinear method reconstructs optical properties before and after changes, showing better tolerance to modeling errors.

More Related Videos

Correlative Microscopy for 3D Structural Analysis of Dynamic Interactions
13:43

Correlative Microscopy for 3D Structural Analysis of Dynamic Interactions

Published on: June 24, 2013

14.6K
Near Infrared Optical Projection Tomography for Assessments of β-cell Mass Distribution in Diabetes Research
15:18

Near Infrared Optical Projection Tomography for Assessments of β-cell Mass Distribution in Diabetes Research

Published on: January 12, 2013

17.0K

Related Experiment Videos

Last Updated: Apr 1, 2026

Computed Tomography-guided Time-domain Diffuse Fluorescence Tomography in Small Animals for Localization of Cancer Biomarkers
12:24

Computed Tomography-guided Time-domain Diffuse Fluorescence Tomography in Small Animals for Localization of Cancer Biomarkers

Published on: July 17, 2012

13.0K
Correlative Microscopy for 3D Structural Analysis of Dynamic Interactions
13:43

Correlative Microscopy for 3D Structural Analysis of Dynamic Interactions

Published on: June 24, 2013

14.6K
Near Infrared Optical Projection Tomography for Assessments of β-cell Mass Distribution in Diabetes Research
15:18

Near Infrared Optical Projection Tomography for Assessments of β-cell Mass Distribution in Diabetes Research

Published on: January 12, 2013

17.0K

Area of Science:

  • Biomedical Optics
  • Medical Imaging
  • Optical Physics

Background:

  • Difference imaging recovers changes in optical properties using pre- and post-change measurements.
  • Conventional methods use linearized difference reconstruction, offering good tolerance to modeling errors but limited quantitative accuracy and spatial resolution.
  • Linearization of nonlinear observation models can lead to qualitative difference images with weak spatial resolution.

Purpose of the Study:

  • To develop and evaluate a nonlinear approach for difference imaging that overcomes the limitations of traditional linear methods.
  • To enable simultaneous reconstruction of optical parameters before and after a change using two datasets.
  • To assess the feasibility and robustness of the nonlinear approach against various modeling errors.

Main Methods:

  • A nonlinear difference imaging method was developed for simultaneous reconstruction of optical parameters from two measurement datasets.
  • The approach was validated using numerical simulations.
  • Experimental data from a phantom study were used to test the method's performance and error tolerance.

Main Results:

  • The nonlinear approach demonstrated improved quantitative accuracy and spatial resolution compared to linearized methods.
  • The method showed feasibility in recovering changes in optical properties.
  • The study investigated the approach's tolerance to common modeling errors, including domain truncation, optode coupling errors, and domain shape errors.

Conclusions:

  • The developed nonlinear difference imaging method offers a promising alternative to conventional linear techniques.
  • Simultaneous reconstruction of pre- and post-change optical parameters enhances image quality and reliability.