Basal Temperature Measurement Using a Multi-Sensor Armband in Australian Young Women: A Comparative Observational
John D Wark1, Lucy Henningham, Alexandra Gorelik
1University of Melbourne, Department of Medicine, Royal Melbourne Hospital, Parkville, Australia. jdwark@unimelb.edu.au.
Background:
The menstrual cycle is a key marker of health in women of reproductive age. Monitoring ovulation is useful in health studies involving young women. The upward shift in basal body temperature, which occurs shortly after ovulation and continues until the next menses, is a potentially useful marker of ovulation, which has been exploited in clinical and research settings.
Objective:
We investigated the utility of BodyMedia SenseWear (BMSW) in monitoring ovulation in young women by analyzing the correlation and agreement of basal temperatures measured using BMSW and a digital oral thermometer.
Methods:
Kappa statistics were used to determine the agreement in ovulation detection between the two devices, for each participant, under each form of analysis. Participants also completed an online questionnaire assessing the acceptability of both devices.
Results:
We recruited 16 participants with 15 of them providing analyzable data (11 OCP non-users, 4 OCP users). Weak to moderate correlations were observed between thermometer and BMSW temperature measurements averaged over 5 different time intervals. However, no agreement between methods was observed using Bland-Altman plots. There was a significant difference in the range of temperatures that each device recorded (thermometer: 35.3-37.2°C, BMSW: 29.7-36.7°C) with BMSW temperatures significantly lower than thermometer temperatures: mean 34.6°C (SD 1.2) versus 36.4°C (SD 0.3) respectively, P<.001. Poor agreement was observed between devices under quantitative analysis of ovulation while fair agreement was observed under visual analysis. Under both quantitative and visual analysis, there was 0% agreement for evidence of ovulation.
Conclusions:
This study demonstrated the importance of evaluating biomeasures collected using mobile monitoring devices by comparison with standard methods. It revealed a relatively poor correlation between BMSW and oral thermometer temperature readings and suggested that BMSW is unlikely to detect an upward shift in basal body temperature. Participant behavior suggested poor compliance in the use of BMSW for basal temperature measurement and that the basal body temperature method may not be suitable for use in unselected samples of young women. There is a need for research tools for monitoring ovulation that are simple, self-administered, and inexpensive, yet appealing to young women.
Related Concept Videos
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...


