Related Experiment Video
Updated: Jan 20, 2026

Growth of Human and Sheep Corneal Endothelial Cell Layers on Biomaterial Membranes
Published on: February 6, 2020
Impact of Corneal Endothelial Dysfunctions on Intraocular Oxygen Levels in Human Eyes
Andrew J W Huang1, Ying-Bo Shui1, Yu-Ping Han2
1Department of Ophthalmology and Visual Sciences, Washington University School of Medicine, St. Louis, Missouri, United States.
Purpose:
We studied the implications of corneal endothelial dysfunctions on oxidative stress in the anterior segment via in vivo measurements of oxygen partial pressure (pO2) in the anterior chamber (AC) of human eyes.
Methods:
We recruited 51 patients undergoing cataract surgery and/or endothelial keratoplasty (EK). Endothelial cell density (ECD; n = 33) and central corneal thickness (CCT; n = 41) were measured on patients with relatively clear corneas. Before surgery, an oxygen sensor was introduced into the AC via a peripheral corneal paracentesis. In all patients, seven measurements of pO2 were obtained by positioning the flexible tip near the endothelium at the central cornea, at four cardinal subendothelial locations near the midperipheral cornea, and in the mid-AC and AC angle. In patients with pseudophakia or eyes undergoing cataract surgery, pO2 also was measured near the lens surface and in the posterior chamber.
Results:
Consistent with our previous reports, a steep oxygen gradient was noted in the anterior segment of normal controls (n = 24). In patients with endothelial dysfunctions (n = 27), there was a significant increase of pO2 at all five subendothelial locations without a significant increase of pO2 in the AC angle. By regression analyses, subendothelial pO2 correlated inversely with ECD and positively with CCT in patients with endothelial dysfunctions.
Conclusions:
This study demonstrates an even steeper intraocular oxygen gradient in eyes with corneal endothelial dysfunctions. It suggests that the reduced oxygen consumption in corneal endothelial cells may increase oxidative stress in the AC and the existence of an alternative aqueous inflow pathway that maintains a relatively low and constant pO2 at the AC angle.
Related Concept Videos
06:23Development of a Noninvasive, Laser-Assisted Experimental Model of Corneal Endothelial Cell Loss
05:20Growth of Human and Sheep Corneal Endothelial Cell Layers on Biomaterial Membranes
08:36A Porcine Corneal Endothelial Organ Culture Model Using Split Corneal Buttons
10:02Use of Rabbit Eyes in Pharmacokinetic Studies of Intraocular Drugs
10:46Corneal Donor Tissue Preparation for Descemet's Membrane Endothelial Keratoplasty
04:11Laser-assisted Selective Ablation of Porcine Corneal Endothelial Cells: A Technique to Induce Focused Porcine Corneal Endothelial Injury for Ex Vivo Studies