Aims:
Typically, myocardial perfusion imaging with two-dimensional (2D) cardiovascular magnetic resonance (CMR) acquires data in three to four myocardial slices at a spatial resolution of 2-3 mm. However, accelerated data acquisition can facilitate higher spatial resolution (<2 mm) or three-dimensional (3D) whole-heart coverage (up to 16 slices). This study aims to compare image quality, diagnostic confidence, and quantitation of myocardial ischaemic burden (MIB) between 2D high-resolution and 3D whole-heart perfusion-CMR.
Methods And Results:
Twenty-seven patients with stable angina underwent both high-resolution 2D and whole-heart 3D perfusion-CMR. Total perfusion defect (TPD) and total scar burden (TSB) areas were contoured and expressed as percentage myocardium. MIB was calculated by subtracting TSB from TPD. Image quality, artefact, and diagnostic confidence scores were similar for both techniques (P>0.05). The mean MIB from high-resolution and 3D acquisition was similar (4.3±5.2% vs. 4.1±4.9%; P=0.81), with a strong correlation between techniques (r=0.72; P<0.001). There was no systematic bias for estimates of MIB between techniques [mean bias=-0.17%, 95% confidence interval (CI): -1.7 to -1.3%] and the 95% limits of agreement were -7.5 to 7.2%. When used to categorize MIB as >10% or <10%, there was only fair agreement between the two techniques (κ=0.29, 95% CI: -0.12 to 0.70).
Conclusion:
There is strong correlation and broad agreement between estimates of MIB from both techniques. However, the 95% limits of agreement are relatively wide and therefore a larger comparative study is needed before they can be considered interchangeable-particularly around the clinically relevant 10% threshold.
More Related Videos
08:13In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
11:13Quantification of Mouse Heart Left Ventricular Function, Myocardial Strain, and Hemodynamic Forces by Cardiovascular Magnetic Resonance Imaging
Published on: May 24, 2021
Related Concept Videos
Imaging Studies for Cardiovascular System IV: CMRI
Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System V: CT