Related Experiment Video
Updated: Apr 1, 2026

Genetic Analysis of Hereditary Transthyretin Ala97Ser Related Amyloidosis
Published on: June 9, 2018
Serial scanning with technetium pyrophosphate (99mTc-PYP) in advanced ATTR cardiac amyloidosis
Adam Castaño1,2, Albert DeLuca3, Richard Weinberg3
1Nuclear Cardiology Laboratory, Columbia College of Physicians & Surgeons, 622 W 168th St. P.H. 10-203, New York, NY, 10032, USA. ac3220@cumc.columbia.edu.
Background:
Development of noninvasive imaging modalities to quantify amyloid burden over time is an unmet clinical need. Technetium pyrophosphate (99mTc-PYP) scintigraphy is a simple and widely available radiotracer useful to differentiate transthyretin from light-chain amyloidosis in patients with advanced cardiac amyloidosis. We examined the utility of serial 99mTc-PYP scanning to quantify amyloid burden over time in TTR cardiac amyloidosis (ATTR-CA).
Methods And Results:
Twenty subjects with ATTR-CA (10 wild type, 10 mutant) underwent serial 99mTc-PYP planar cardiac imaging. Cardiac retention was assessed both semiquantitatively (visual score 0, no uptake to 3, uptake greater than bone) and quantitatively (region of interest drawn over the heart, copied, and mirrored over the contralateral chest) to calculate a heart-to-contralateral (H/CL) ratio. Index scan mean visual score and H/CL were 3.0 ± 0.2 and 1.79 ± 0.2, respectively, and after an average 1.5 ± 0.5 years follow-up, did not differ, 3.0 ± 0.2, P = .33 and 1.76 ± 0.2, P = .44. H/CL change was minimal, 0.03 ± 0.17, did not correlate with time between scans, r = 0.19, P = .43, and was observed despite obvious clinical progression (increase in troponin ≥ 0.1 ng/mL, BNP ≥ 400 pg/mL, NYHA class, and/or death).
Conclusions:
Serial 99mTc-PYP scanning in subjects with advanced ATTR-CA does not show significant changes over an average 1.5 years of follow-up despite obvious clinical progression.
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
![Dynamic Imaging of Chimeric Antigen Receptor T Cells with [18F]Tetrafluoroborate Positron Emission Tomography/Computed Tomography](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F62334.jpg&w=3840&q=50)