Quantitative evaluation of background parenchymal enhancement (BPE) on breast MRI. A feasibility study with a
Alberto Tagliafico1, Bianca Bignotti2, Giulio Tagliafico3
11 Institute of Anatomy, Department of Experimental Medicine, University of Genoa, Genova, Italy.
Objective:
To evaluate quantitative measurements of background parenchymal enhancement (BPE) on breast MRI and compare them with observer-based scores.
Methods:
BPE of 48 patients (mean age: 48 years; age range: 36-66 years) referred to 3.0-T breast MRI between 2012 and 2014 was evaluated independently and blindly to each other by two radiologists. BPE was estimated qualitatively with the standard Breast Imaging Reporting and Data System (BI-RADS) scale and quantitatively with a semi-automatic and an automatic software interface. To assess intrareader agreement, MRIs were re-read after a 4-month interval by the same two readers. The Pearson correlation coefficient (r) and the Bland-Altman method were used to compare the methods used to estimate BPE. p-value <0.05 was considered significant.
Results:
The mean value of BPE with the semi-automatic software evaluated by each reader was 14% (range: 2-79%) for Reader 1 and 16% (range: 1-61%) for Reader 2 (p > 0.05). Mean values of BPE percentages for the automatic software were 17.5 ± 13.1 (p > 0.05 vs semi-automatic). The automatic software was unable to produce BPE values for 2 of 48 (4%) patients. With BI-RADS, interreader and intrareader values were κ = 0.70 [95% confidence interval (CI) 0.49-0.91] and κ = 0.69 (95% CI 0.46-0.93), respectively. With semi-automated software, interreader and intrareader values were κ = 0.81 (95% CI 0.59-0.99) and κ = 0.85 (95% CI 0.43-0.99), respectively. BI-RADS scores correlated with the automatic (r = 0.55, p < 0.001) and semi-automatic scores (r = 0.60, p < 0.001). Automatic scores correlated with the semi-automatic scores (r = 0.77, p < 0.001). The mean percentage difference between automatic and semi-automatic scores was 3.5% (95% CI 1.5-5.2).
Conclusion:
BPE quantitative evaluation is feasible with both semi-automatic and automatic software and correlates with radiologists' estimation.
Advances In Knowledge:
Computerized BPE quantitative evaluation is feasible with both semi-automatic and automatic software. Computerized BPE quantitative scores correlate with radiologists' estimation.
Related Concept Videos
Magnetic Resonance Imaging
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies IV: Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System IV: CMRI