Related Experiment Video
Updated: Mar 31, 2026

Noninvasive Determination of Vortex Formation Time Using Transesophageal Echocardiography During Cardiac Surgery
Published on: November 28, 2018
Intraoperative improvement in left ventricular peak systolic velocity predicts better short-term outcome after
Jo Eidet1, Gry Dahle2, Jan Frederik Bugge3
1The Intervention Centre, Rikshospitalet, Oslo University Hospital, Oslo, Norway Institute of Clinical Medicine, Faculty of Medicine, University of Oslo, Oslo, Norway.
Objectives:
Left ventricular function is expected to improve after transcatheter aortic valve implantation due to the acute reduction in afterload, but does not occur in all patients. We hypothesized that the immediate intraoperative response in systolic left ventricular longitudinal motion during the procedure could be a predictor of short-term outcome.
Methods:
Sixty-four patients treated with transcatheter aortic valve implantation for severe aortic stenosis were included. Transoesophageal 4- and 2-chamber echocardiograms were obtained immediately prior to and ∼15 min after valve implantation. Patients were defined as responders if their average left ventricular longitudinal peak systolic velocity increased by ≥20% from the preimplantation value and was related to the 3-month outcome.
Results:
Thirty-five patients were classified as responders, with an increase in the intraoperative longitudinal peak systolic velocity from an average of 2.2 ± 0.8 to 3.1 ± 1.1 cm/s (P < 0.001); the velocity was unchanged in the remaining 29 patients, who averaged 2.4 ± 1.1 cm/s. There were significantly fewer adverse cardiac events in the responder group at the 3-month follow-up (20 vs 45%, P = 0.03) and the New York Heart Association class was significantly better in the responders compared with non-responders. Responders had a significant reduction in N-terminal probrain natriuretic peptide levels [243 (113-361) vs 163 (64-273), P = 0.004] at the 3-month follow-up, whereas non-responders did not [469 (130-858) vs 289 (157-921), P = 0.48].
Conclusions:
An immediate improvement in the longitudinal peak systolic velocity during the transcatheter aortic valve implantation procedure predicted a better short-term outcome and may be useful in identifying patients who are at risk of a less favourable outcome after transcatheter aortic valve implantation.
More Related Videos
08:19Transthoracic Echocardiography to Assess Post-Resuscitation Left Ventricular Dysfunction After Acute Myocardial Infarction and Cardiac Arrest in Pigs
Published on: July 12, 2022
09:57Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022