Related Experiment Video
Updated: Mar 31, 2026

Asthma Detection Research Based on Voice Signal Processing and Machine Learning
Published on: July 22, 2025
[The Evaluation of Voice Quality via Signal Typing in Voice using Narrowband Spectrograms]
B Barsties1, U Hoffmann2, Y Maryn1
1Faculty of Medicine and Health Sciences, University of Antwerp, Belgium.
Objective:
Traditionally, voice quality is evaluated by auditory-perceptual judgment but objective-acoustic analyses are also valid tools. Spectrography is a part of objective-acoustic analyses and is used since around 50 years. Recently, Sprecher et al. (2010) designed a new classification scheme for signal typing in voice using narrowband spectrograms. The present study aimed to explore the external validation between these 2 methods in a larger dataset.
Materials And Methods:
In total 300 voice samples were used based on the vowel [a:], in which n=270 had various degrees of dysphonia and n=30 were vocally normal. All voice samples were evaluated by 7 speech-language therapists using the RBH-scale and 2 judges analyzed the signal typing in voice using narrowband spectrograms.
Results:
The intra- and inter-rater reliability of all RBH parameters was fair in average (kappa=0.234-0.383) but the rater reliability was moderate between the 2 judges rating signal typing in voice (kappa=0.457). A strong concurrent validity was identified between the signal typing in voice using narrowband spectrograms and auditory-perceptual judgment of hoarseness and breathiness (H: r=0.746, p=0.000; B: r=0.746, p=0.000) but only fair in roughness (r=0.370, p=0.000).
Conclusion:
The present results confirmed the results of Sprecher et al. (2010) and it might be meaningful to benefit signal typing in voice using narrowband spectrograms on sustained vowels as a valid complement in the evaluation of hoarseness and breathiness for clinical utility and research.
Related Concept Videos
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Bode Plots
A network function represents the ratio of a system's output to its input, with the magnitude and phase angle derived from the complex network function. The decibel logarithmic gain is...
Classification of Signals
A continuous-time signal holds a value at every instant in time, representing information seamlessly. In contrast, a discrete-time signal holds values only at specific moments, often denoted as x(n), where...
Bandpass Sampling
A bandpass signal has a spectrum with a lower frequency limit, denoted as ω1, and an upper frequency limit, denoted as ω2....
Aliasing
If the sampling frequency is below the Nyquist rate, these replicas overlap, preventing the original...
Design Example

