Abnormalities in jugular venous flow velocity in pulmonary hypertension
1Department of Medicine, St. Michael's Hospital, Toronto, Ontario, Canada.
Abstract:
Doppler recordings of jugular venous flow velocity previously performed in this laboratory in patients with pulmonary hypertension had shown variations from the normal dominant systolic flow (SF) greater than diastolic flow (DF), to SF = DF, SF less than DF or DF alone. The mechanisms underlying these flow alterations were studied in 25 patients and correlated with hemodynamics. The patients with abnormal flow patterns had increased right atrial V-wave pressures. This was associated with an increased right ventricular early diastolic pressure. The incidence of clinical heart failure was higher in patients with SF less than DF or DF alone (8 of 11) compared with 5 of 10 patients with SF = DF. Thus, in patients with pulmonary hypertension, the abnormal jugular venous flow patterns appear to be caused by both an increased DF velocity and a decrease in SF velocity. Because the right atrial V-wave pressures were similar in patients with both SF = DF and SF less than DF or DF alone and the incidence of heart failure was higher in the latter, the decrease in SF must be a later phenomenon. Serial observations confirmed this temporal sequence. The applicability of these observations to bedside evaluation of patients with pulmonary hypertension is emphasized.
Related Concept Videos
Venous Return
What is Venous Return?
Venous return refers to the rate at which blood flows back to the heart from the body's peripheral veins. It's an integral part of the circulatory system as it...
Pulmonary Hypertension: Classification and Pathogenesis
There are various classifications for PH, each relating to different underlying causes and also...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection
Cardiovascular System Abnormal Findings II: Auscultation
Abnormal Heart Sounds
Gallops:
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies