Related Experiment Video
Updated: Mar 31, 2026
![Semi-quantitative Assessment Using [18F]FDG Tracer in Patients with Severe Brain Injury](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F58641.jpg&w=3840&q=50)
Semi-quantitative Assessment Using [18F]FDG Tracer in Patients with Severe Brain Injury
Published on: November 9, 2018
A second look at the utility of serial routine repeat computed tomographic scans in patients with traumatic brain
Ansab A Haider1, Peter Rhee1, Tahereh Orouji1
1Division of Trauma and Acute Care Surgery, Department of Surgery, University of Arizona Medical Center, 501 North Campbell Avenue, Room 5411, PO Box 245063, Tucson, AZ, 85724, USA.
Background:
The practice of a routine repeat head computed tomographic scans in patients with traumatic brain injury (TBI) is under question. The aim of our study was to evaluate the utility of a more than 1 repeat head computed tomography (M1CT) scans in patients with TBI.
Methods:
We performed a 3-year analysis of a prospectively collected database of all TBI patients presenting to our level I trauma center. Patients who received M1CT scans were included. Findings and reason (without neurologic decline vs after neurologic decline) for M1CT were recorded. Primary outcome measure was neurosurgical intervention.
Results:
A total of 296 patients that underwent M1CT were included. Of those, 291 patients (98.6%) had M1CT without a neurologic decline, and neurosurgical intervention was performed in 1 patient (.3%) who was inexaminable (Glasgow coma scale score = 6). The remaining (n = 5) had M1CT due to a neurologic decline; 4 patients (80%) of the 5 had worsening of ICH; and neurosurgical intervention was performed in 3 (75%) of the 4 patients.
Conclusions:
The practice of multiple repeat head computed tomographic scans should be limited to inexaminable patients or patients with neurological deterioration.
More Related Videos
10:33Advanced Diffusion Imaging in The Hippocampus of Rats with Mild Traumatic Brain Injury
Published on: August 14, 2019
08:27Development of an Uncomplicated Mild Traumatic Brain Injury Model Modified by Weight-Drop Method and Evidenced by Magnetic Resonance Imaging
Published on: April 11, 2025
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Brain Imaging
These technologies include computerized axial tomography (CAT or CT scans), positron-emission tomography (PET scans), magnetic resonance imaging (MRI), functional magnetic resonance imaging (fMRI), and Transcranial Magnetic...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT