Abstract:
The amplification of RNA is becoming increasingly important, as often only limited amounts of cells are available for gene expression analysis. In this study, the gene expression profile of the 39 human homeobox (HOX) genes was analyzed in bone marrow-derived multipotent stromal cells (BM-MSCs) by reverse transcription (RT-) and quantitative polymerase chain reaction (qPCR). For further unlimited gene expression analysis, Whole Transcriptome Amplification (WTA) was used to amplify RNA from human BM-MSCs. However, WTA led to biased RT- and qPCR results, and even non-detectability of HOX transcripts compared to non-amplified BM-MSC samples which instead revealed transcription. It is important to note that the same RNA of the respective human BM-MSC line was used for normal cDNA synthesis by standard reverse transcription (non-amplified RT samples) and for cDNA synthesis by WTA (amplified WTA samples). On this account, the different RT- and qPCR results were unexpected applying WTA. The significantly reduced detection of HOX transcripts after WTA has been demonstrated for numerous BM-MSC lines (n = 26) by RT-PCR analysis. Furthermore, undetectable HOX transcripts meaning HOX transcripts of human BM-MSCs that were detected after normal cDNA synthesis, but were no longer detectable after WTA, were consistently observed by qPCR analysis. Finally, qPCR experiments revealed a possible explanation for the differences between amplified and non-amplified BM-MSC samples: an inverse correlation between the biased qPCR results and the low expression level of the respective HOX gene. The PCR analysis of high-copy transcripts like GAPDH or RPL13A revealed unchanged qPCR results after WTA compared to corresponding non-amplified BM-MSC samples. In contrast, WTA led to biased qPCR results for medium-copy HOX transcripts, and even non-detectability of low-copy HOX transcripts of human BM-MSCs resulting in false negative RT- and qPCR data applying WTA.
Related Concept Videos
PCR
Real Time RT-PCR
The real-time quantification of the number of amplified products is...
RACE - Rapid Amplification of cDNA Ends
PCR - Polymerase Chain Reaction