Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
A multicenter validation study of Doppler ultrasound versus angiography
G Howard1, L E Chambless2, W H Baker3
1From the Department of Public Health Sciences, Bowman Gray School of Medicine, Winston-Salem, NC, USA; The Department of Neurology, Bowman Gray School of Medicine, Winston-Salem, NC, USA.
Abstract:
The establishment of 60% or greater diameter stenosis by Doppler ultrasound is an eligibility requirement of the Asymptomatic Carotid Atherosclerosis Study (ACAS). We used a uniform statistical approach for each of 30 Doppler devices to establish a cutpoint for the peak systolic flow to insure a positive predictive value of 90% in predicting a 60%+ stenosis by angiography. Data were analyzed by device; however, performance relates to the device-sonographer-reader system. For those devices reporting in peak systolic velocity, cutpoints ranged from 151 to 390 cm/s, and for those reporting a peak systolic frequency from 5,400 to 11,250 Hz. Eighteen devices had a sensitivity above 60%, and nine devices had a sensitivity above 80%. However, for six instruments, the relationship between Doppler and angiography was too weak to establish any cutpoint. In addition, for one instrument a value could be established, but the associated sensitivity was only 18%. This remarkable variability in the performance is at odds with the high sensitivity uniformly published in the literature, suggesting (a) that the high reported sensitivity for Doppler may represent an overestimate of average performance, perhaps due to publication bias, (b) the paramount need for documented quality control measures within local laboratories to insure that Doppler examinations are performed reliably, and (c) the need for caution in the generalization of results among laboratories.
More Related Videos
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Imaging Studies VII: Vascular Imaging