Quantification of normal cerebral oxygen extraction and oxygen metabolism by phase-based MRI susceptometry:
Robin Kämpe1, Emelie Lind1, Freddy Ståhlberg1,2
1Department of Medical Radiation Physics, Lund University, Lund, Sweden.
Introduction:
Global oxygen extraction fraction (OEF) and cerebral metabolic rate of oxygen (CMRO2 ) were quantified in a test-retest study. Cerebral blood flow (CBF) data, required for CMRO2 estimation, were obtained using dynamic susceptibility contrast MRI (DSC-MRI). OEF and CMRO2 were quantified using two separate data sets, that is, conventional high-resolution (HR) gradient echo (GRE) phase maps as well as echo planar imaging (EPI) phase maps taken from the baseline (precontrast) part of the DSC-MRI time series. The EPI phase data were included to elucidate whether an extra HR-GRE scan is needed to obtain information about OEF and CMRO2 , or if this information can be extracted from the DSC-MRI experiment only.
Methods:
Twenty healthy volunteers were scanned using 3 T MRI on two occasions. Oxygen saturation levels were obtained from phase data measured in the great cerebral vein of Galen, based on HR-GRE as well as EPI phase maps. In combination with DSC-MRI CBF, this allowed for calculation of OEF and CMRO2 .
Results:
High-resolution-gradient echo- and EPI-based phase images resulted in similar OEF spread and repeatability, with coefficients of variation/intraclass correlation coefficients of 0·26/0·95 and 0·23/0·81, respectively. Absolute OEF values (HR-GRE: 0·40 ± 0·11, EPI: 0·35 ± 0·08) were consistent with literature data. CMRO2 showed similar repeatability, somewhat increased spread and reasonable absolute values (HR-GRE: 3·23 ± 1·26 ml O2 /100 g min-1 , EPI: 2·79 ± 0·89 ml O2 /100 g min-1 ).
Discussion:
In general, the results obtained by HR-GRE and EPI showed comparable characteristics. The EPI methodology could potentially be improved using a slightly modified DSC-MRI protocol (e.g. with regard to spatial resolution and slice gap).