Lung function in very preterm infants with patent ductus arteriosus under conservative management: an observational
Hsiu-Lin Chen1,2, Rei-Cheng Yang3,4, Wei-Te Lee5
1Department of Respiratory Therapy, College of Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan. ch840062@kmu.edu.tw.
Background:
Persistent patent ductus arteriosus (PDA) during hospitalization is thought to be associated with adverse pulmonary outcomes in very preterm infants. This observational study aimed to compare the lung function in very preterm infants with and without PDA at discharge.
Methods:
Very preterm infants, admitted to our neonatal intensive unit, who required respiratory support soon after birth and had undergone a lung function test at discharge, were enrolled. Infants with a need for positive-pressure support (either an invasive ventilator, or nasal continuous positive airway pressure without oxygen) or supplemental oxygen at a postmenstrual age of 36 weeks were defined as having bronchopulmonary dysplasia (BPD). Echocardiography was performed weekly for each of the very preterm infants with PDA to confirm closure of the PDA. The data were collected retrospectively.
Results:
Fifty-two very preterm infants received lung function tests before discharge during the study period, 28 of whom had PDA and received conservative management, and 20 who did not. The other 4 infants who were given active treatment for PDA were excluded. Gestational age was significantly smaller in the PDA group than in the no-PDA group (27.1 ± 2.0 vs. 28.6 ± 1.6 weeks, p = 0.009). Birth weight did not differ significantly in those with and those without PDA (0.98 ± 0.26 vs. 1.12 ± 0.26 kg, p = 0.074). Significantly more infants with PDA had BPD (p = 0.002) and required respiratory support for a longer period (p = 0.001) than those without PDA. However, functional residual capacity (ml/kg) at discharge was comparable between the two groups after adjusting for gestational age and postmenstrual age at testing (21.6 ± 8.4 vs. 21.5 ± 6.7 ml/kg, p = 0.894). Other lung function test parameters were also comparable.
Conclusion:
Under a definition of BPD (including infants needing CPAP but without oxygen) other than the conventional definition, the very preterm infants in our study who received conservative management for PDA had a higher percentage of BPD than the infants without PDA. The parameters of the lung function test and lung clearance index were comparable between these two groups at discharge.
More Related Videos
09:31Normothermic Negative Pressure Ventilation Ex Situ Lung Perfusion: Evaluation of Lung Function and Metabolism
Published on: February 14, 2022
08:58Development of a Neonatal Piglet Acute Lung Injury Model Recreating the Early Environment of Preterm Infant Lungs
Published on: October 31, 2025
Related Concept Videos
Pneumonia V: Nursing management and Prevention
The nurse must practice strict medical asepsis and adhere to infection control guidelines to minimize healthcare-associated infections.
Enhance airway patency
Position the patient correctly to facilitate drainage of the affected lung segments. Manual or mechanical percussion and vibration can also be employed....
Chronic Obstructive Pulmonary Disease-V: Management
Smoking Cessation
Cardiopulmonary Resuscitation II: ACLS Airway Management