Related Experiment Video
Updated: Mar 31, 2026

Development of an Electrochemical DNA Biosensor to Detect a Foodborne Pathogen
Published on: June 3, 2018
Inactivation of Bacillus cereus spores in a tsuyu sauce using continuous ohmic heating with five sequential
J H Ryang1,2, N H Kim1, B S Lee2
1Department of Biotechnology, College of Life Sciences and Biotechnology, Korea University, Seoul, Korea.
Aims:
The effect of ohmic heating (OH) in a pilot plant system which had a zig-zag shaped (elbow-type) ohmic heater with five sequential voltage electrodes was investigated on Bacillus cereus spores in a commercial tsuyu sauce.
Methods And Results:
The electrical field was fixed at 26·7 V cm(-1) with an alternating current frequency of 25 kHz. Raw tsuyu sauce (50 l) inoculated with B. cereus spores was submitted in a 4 × 3 factorial design to the OH system and heated at 95, 105, 115, and 125°C each for 30, 60, and 90 s. Survival of B. cereus spores and colour change in the commercial tsuyu sauce were both measured before and after treatment. As the treatment temperature and time increased, the number of surviving B. cereus spores decreased. The OH treatment in a bath-type process at 105°C for more than 30 s resulted in the total inactivation of the inoculated B. cereus spores (average 5·4 log reductions to undetectable levels after treatment). The OH protocol of heating at 105°C for 60 s which ensure complete eradication of the inoculated spores without compromising product quality was chosen and investigated for its suitability for commercial application on bulk quantities of samples (500 l). Reliable and reproducible reductions in B. cereus spore counts of 4·7-5·5 log CFU ml(-1) (mean ± standard deviation = 5·1 ± 0·3 CFU ml(-1) ) were achieved by the selected protocol of the continuous OH treatment (105°C for 60 s).
Conclusion:
This study suggests that OH treatment with five sequential elbow-type electrodes has great potential as an industrial sterilizing method for liquid food contaminated with B. cereus spores.
Significance And Impact Of The Study:
This procedure will enhance the microbiological quality of liquid foods while minimizing quality deterioration.
More Related Videos
07:07Controlled-release of Chlorine Dioxide in a Perforated Packaging System to Extend the Storage Life and Improve the Safety of Grape Tomatoes
Published on: April 7, 2017
14:17The Portable Chemical Sterilizer PCS, D-FENS, and D-FEND ALL: Novel Chlorine Dioxide Decontamination Technologies for the Military
Published on: June 29, 2014
Related Concept Videos
Physical Methods for Controlling Microbial Growth: Temperature
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Physical Methods for Controlling Microbial Growth: Radiation and Filtration