Related Experiment Video
Updated: Mar 31, 2026

Author Spotlight: Enhancing Vascular Function and Physical Capacity in Cardiovascular Disease Through Novel Interventions and NIRS Technology
Published on: March 22, 2024
Vascular responsiveness determined by near-infrared spectroscopy measures of oxygen saturation
Kaitlin M McLay1,2, Federico Y Fontana3, Josh P Nederveen1,2
1Canadian Centre for Activity and Aging, The University of Western Ontario, London, ON, Canada.
Abstract:
Vascular impairments at the macro- and microcirculatory levels are associated with increased risk for cardiovascular disease. Flow-mediated dilation (FMD) is currently the most widely used method for non-invasive assessment of vascular endothelial function. Recently, near-infrared spectroscopy (NIRS)-derived measures of tissue oxygen saturation (StO2) have been used to characterize the dynamic response of local tissue perfusion to a brief period of ischaemia. The purpose of the present study was to establish correlations between the reperfusion rate of StO2 and FMD. Ultrasound-derived FMD was quantified after 5 min of distal cuff occlusion of the popliteal artery in 20 healthy young men (26 ± 3 years old). Triplicate measurements of end-diastolic arterial diameter were made every 15 s after cuff release, and FMD response was calculated as the greatest percentage change in diameter from baseline (%FMD). The StO2 was measured using NIRS throughout the duration of each test. Two consecutive FMD tests were performed, separated by 30 min of rest, and were averaged for %FMD and StO2. The %FMD was significantly correlated with the reperfusion slope of StO2 after cuff release (slope 2 StO2; r = 0.63, P = 0.003). In conclusion, the present study established a correlation between slope 2 StO2 and %FMD in healthy young men. These data suggest that NIRS-derived slope 2 StO2 can be used as a measure of vascular endothelial function.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
09:04Skeletal Muscle Neurovascular Coupling, Oxidative Capacity, and Microvascular Function with 'One Stop Shop' Near-infrared Spectroscopy
Published on: February 20, 2018
Related Concept Videos
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...