Bifocal left ventricular stimulation or the optimal left ventricular stimulation site in cardiac resynchronization
Gerben Jan de Roest1, LiNa Wu2, Carel C de Cock2
1Department of Cardiology, Institute for Cardiovascular Research (ICaR-VU), VU University Medical Center, De Boelelaan 1118, Amsterdam1081 HV, The Netherlands gj.deroest@vumc.nl.
Aims:
Several implantation strategies have been proposed to improve response to cardiac resynchronization therapy (CRT), including bifocal left ventricular (LV) stimulation and optimal single-LV lead placement. This study aimed to compare these two strategies during invasive pressure-volume (PV) loop measurements.
Methods And Results:
Thirty-three patients eligible for CRT were included [21 (64%) men, 20 (61%) ischaemic aetiology, QRS 155 ± 23 ms], and underwent cardiac magnetic resonance (CMR) imaging and invasive PV loop measurements. Left ventricular pump function was characterized by stroke work (SW) and dP/dtmax (5.1 ± 3.4 L mmHg and 856 ± 190 mmHg/s, respectively). Haemodynamic response was assessed during stimulation at single-LV sites and during bifocal LV [anterolateral and posterolateral (PL)] stimulation. Response during bifocal LV stimulation was not significantly higher compared with standard PL pacing (SW; β = 9.4 ± 5.4, P = 0.080; dP/dtmax, β = 0.2 ± 1.9, P = 0.922). However, mean pump function improvement was significantly higher during stimulation at the optimal LV site compared with bifocal LV stimulation (SW; β = 12.7 ± 5.1, P = 0.012; dP/dtmax, β = 3.3 ± 1.2, P = 0.020). Myocardial tissue properties were assessed by CMR tissue tagging. Mechanical activation at the optimal LV site was significantly more delayed compared with the worst LV site (431 ± 93 ms vs. 326 ± 127 ms; P = 0.004).
Conclusion:
Stimulation at the optimal LV site showed a significantly higher pump function improvement compared with bifocal LV stimulation. Mechanical activation at the optimal LV site was significantly more delayed compared with the non-optimal LV site. In general, these results suggest that implantation of a second LV lead yields no additional benefit over implantation of one optimally placed LV lead. However, a bifocal approach might be beneficial in the individual patient.
Related Concept Videos
Cardiomyopathy V: Interprofessional Care
Heart Failure VI: Adjunct Therapies