Related Experiment Video
Updated: Mar 31, 2026

Protease- and Acid-catalyzed Labeling Workflows Employing 18O-enriched Water
Published on: February 20, 2013
Extracting Accurate Precursor Information for Tandem Mass Spectra by RawConverter
Lin He1, Jolene Diedrich1, Yen-Yin Chu2
1Department of Chemical Physiology, The Scripps Research Institute , 10550 North Torrey Pines Road, La Jolla, California 92037, United States.
RawConverter software improves mass spectrometry data extraction from Thermo Fisher RAW files. It enhances peptide and protein identification by accurately associating precursor mass-to-charge values with tandem mass spectra.
Area of Science:
- Proteomics
- Computational Biology
- Mass Spectrometry Data Analysis
Background:
- Mass spectrometry data analysis relies on accurate extraction from proprietary RAW files.
- High-resolution mass spectrometers provide valuable data for peptide/protein identification and quantification.
- Existing tools may not fully leverage high-accuracy mass data.
Purpose of the Study:
- To develop a software tool for improved data extraction from Thermo Fisher mass spectrometer RAW files.
- To enhance the accuracy of precursor mass-to-charge (m/z) values associated with tandem mass spectra.
- To facilitate downstream peptide and protein identification and quantification.
Main Methods:
- Developed RawConverter, a stand-alone software tool for RAW file data extraction.
- RawConverter extracts full scan and MS(n) data, associating accurate precursor m/z values.
- Supports data-dependent acquisition (DDA) and data-independent acquisition (DIA) with multiple output formats (MS1/MS2/MS3, MGF, mzXML).
Main Results:
- RawConverter significantly improves peptide spectra matches (PSMs) and subsequent peptide/protein identifications compared to ProteoWizard, pXtract, and RawXtract.
- Demonstrated increases in peptide identifications ranging from 17.4% to 45.7% and protein identifications from 13.0% to 36.2%.
- The software accurately associates precursor m/z values, crucial for enhanced identification accuracy.
Conclusions:
- RawConverter is an effective tool for extracting high-quality data from Thermo Fisher RAW files.
- The software enhances the accuracy of mass spectrometry data analysis, leading to improved proteomic identifications.
- Freely accessible software that supports common data formats for broad usability in proteomics research.
Related Concept Videos
Tandem Mass Spectrometry
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
MALDI-TOF Mass Spectrometry
Mass Spectrum: Interpretation
High-Resolution Mass Spectrometry (HRMS)
Mass Spectrometers

