Related Experiment Video
Updated: Mar 31, 2026

10:22
MRM Microcoil Performance Calibration and Usage Demonstrated on Medicago truncatula Roots at 22 T
Published on: January 16, 2021
6.0K
Temporal analysis of Z-Gradient coil eddy currents in tungsten collimator with different resistivities for SPECT/MRI
Amine Samoudi1, Karen Van Audenhaege2, Günter Vermeeren1
1INTEC, Ghent University/iMinds, Ghent, Belgium.
EJNMMI Physics
|October 27, 2015
Abstract
No abstract available in PubMed .
Related Concept Videos
Magnetic Field Due To A Thin Straight Wire
6.7K
Consider an infinitely long straight wire carrying a current I. The magnetic field at point P at a distance a from the origin can be calculated using the Biot-Savart law.
6.7K
Magnetic Susceptibility and Permeability
2.7K
In linear magnetic materials, like paramagnets and diamagnets, magnetization is proportional to the magnetic field intensity. The constant of proportionality, a dimensionless number, is called magnetic susceptibility. The value of the susceptibility depends on the type of material.
When diamagnetic materials are placed under an external magnetic field, the moments opposite to the field are induced. Hence, the susceptibility for diamagnets has a minimal negative value of 10-5–10-6. Since...
When diamagnetic materials are placed under an external magnetic field, the moments opposite to the field are induced. Hence, the susceptibility for diamagnets has a minimal negative value of 10-5–10-6. Since...
2.7K
Magnetic Field Due to Two Straight Wires
5.4K
Consider two parallel straight wires carrying a current of 10 A and 20 A in the same direction and separated by a distance of 20 cm. Calculate the magnetic field at a point "P2", midway between the wires. Also, evaluate the magnetic field when the direction of the current is reversed in the second wire.
5.4K
Magnetic Field Of A Current Loop
6.9K
Consider a circular loop with a radius a, that carries a current I. The magnetic field due to the current at an arbitrary point P along the axis of the loop can be calculated using the Biot-Savart law.
6.9K
Divergence and Curl of Magnetic Field
4.2K
The magnetic field due to a volume current distribution given by the Biot–Savart Law can be expressed as follows:
4.2K
Induced Electric Fields: Applications
2.9K
An important distinction exists between the electric field induced by a changing magnetic field and the electrostatic field produced by a fixed charge distribution. Specifically, the induced electric field is nonconservative because it does not work in moving a charge over a closed path. In contrast, the electrostatic field is conservative and does no net work over a closed path. Hence, electric potential can be associated with the electrostatic field but not the induced field. The following...