Related Experiment Video
Updated: Mar 31, 2026

Author Spotlight: A Reproductive Hysteroscopy Approach for Complete Endometrial Polyp Removal and Enhanced Endometrial Receptivity
Published on: August 2, 2024
Hysteroscopic sterilization in immunocompromised patients who have intrauterine devices in place: two case reports
Camille Ladanyi1, Carlie Field2, Kristina Tocce3
1Department of Obstetrics and Gynecology, Maine Medical Center, 22 Bramhall Street, Portland, ME, 04102, USA. Cladanyi5@gmail.com.
Introduction:
The micro-inserts used in the hysteroscopic sterilization procedure elicit a benign occlusive tissue response leading to permanent tubal occlusion. Little is known about whether immunosuppressed patients mount the immunological response necessary to ensure tubal occlusion. Theoretical concern for non-occlusion has limited the use of hysteroscopic sterilization in patients on immunosuppressive therapies. In all patient populations, if an intrauterine device is in place, it is usually removed at the time of hysteroscopic sterilization. Little is known about maintaining intrauterine devices during the 3-month period to tubal occlusion.
Case Presentation:
Our patient in case 1 was a 35-year-old Hispanic woman, gravida 2, para 2002, with a history of a living donor kidney transplant. Our patient in case 2 was a 32-year-old Hispanic woman, gravida 3, para 2103, diagnosed with undifferentiated autoimmune disease. Both patients underwent hysteroscopic sterilization. In both cases, a levonorgestrel intrauterine device was in place for contraception. At the time of micro-insert placement, our patients were both on daily immunosuppressive medications, including long-term glucocorticoids. Three months after the hysteroscopic procedure, both patients had successful tubal occlusion, demonstrated by a hysterosalpingogram.
Conclusion:
Hysteroscopic sterilization in an outpatient setting is a reasonable option for sterilization in immunocompromised patients on immunosuppressive therapies. Intrauterine devices can be maintained during the procedure and during the 3-month period to tubal occlusion.
More Related Videos
05:46Introduction of Intracapsular Rotary-cut Procedures IRCP: A Modified Hysteromyomectomy Procedures Facilitating Fertility Preservation
Published on: January 17, 2019
11:44Establishment of a Rat Model for Intrauterine Adhesions via Dual Injury: Curettage and Infection
Published on: October 3, 2025
Related Concept Videos
Intrauterine Drug Delivery Systems
Birth Control Methods
In Vitro Fertilization
The IVF process begins with ovarian stimulation, during which reproductive endocrinologists prescribe hormonal medications to stimulate the ovaries to produce multiple eggs instead of the single...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...