Doppler study of umbilical artery blood flow waveform. Should we use an instrument-adapted nomogram?
J S Abramowicz1, J Arrington, D L Levy
1Division of Maternal-Fetal Medicine, Eastern Virginia Medical School, Norfolk 23507.
Doppler studies of umbilical artery blood flow waveform are becoming an accepted tool of antenatal estimation of fetal well-being. The S/D ratio of the systolic peak (S) to the end-diastolic (D) frequency is the most commonly used parameter. Nomograms relating S/D ratio to gestational age have been published both for normal and pathologic pregnancies. Three hundred twelve analyses of umbilical artery blood flow were performed by continuous Doppler technology in normal, well-dated pregnancies using either one of the following instruments: GE 3600 (GE) or Multigon 500A (MG). Both instruments showed a decrease of S/D with GA, but, by use of a nonpaired t test, a statistically significant difference was found between the two machines. Data on the system used for a particular study should be provided; nomograms for this particular instrument should be consulted and the same machine should be employed for repeat testing in longitudinal studies.
Doppler studies of umbilical artery blood flow waveform are becoming an accepted tool of antenatal estimation of fetal well-being. The S/D ratio of the systolic peak (S) to the end-diastolic (D) frequency is the most commonly used parameter. Nomograms relating S/D ratio to gestational age have been published both for normal and pathologic pregnancies. Three hundred twelve analyses of umbilical artery blood flow were performed by continuous Doppler technology in normal, well-dated pregnancies using either one of the following instruments: GE 3600 (GE) or Multigon 500A (MG). Both instruments showed a decrease of S/D with GA, but, by use of a nonpaired t test, a statistically significant difference was found between the two machines. Data on the system used for a particular study should be provided; nomograms for this particular instrument should be consulted and the same machine should be employed for repeat testing in longitudinal studies.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: