Related Experiment Video
Updated: Mar 30, 2026

Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
Diagnosing Paroxysmal Atrial Fibrillation in Patients With Ischemic Strokes and Transient Ischemic Attacks Using
Kristoffer Grundtvig Skaarup1, Hanne Christensen2, Nis Høst3
1Department of Neurology, Bispebjerg Hospital, University of Copenhagen, Denmark; Department of Cardiology, Gentofte Hospital, University of Copenhagen, Denmark.
Abstract:
Twenty-five to 35 percentage of stroke cases are cryptogenic, and it has been demonstrated that paroxysmal atrial fibrillation (AF) is the causal agent in up to 25% of these incidents. The purpose of this study was to investigate if left atrial (LA) parameters have value for diagnosing paroxysmal AF in patients with ischemic stroke (IS) and transient ischemic attack (TIA). We retrospectively analyzed 219 patients who after acute IS or TIA underwent a transthoracic echocardiographic examination. Patients were designated as patients with paroxysmal AF if they had one or more reported incidents of AF before or after their echocardiographic examination. Patients in the paroxysmal AF group were significantly older and had higher CHA2DS2-VASc score than patients without paroxysmal AF (p <0.05 for both). None of the conventional echocardiographic parameters were significantly associated with paroxysmal AF. However, the atrial measurements evaluating LA function (min LA volume and LA emptying fraction) were significantly different (LA emptying fraction: 45% ± 10% vs 50% ± 10%, p = 0.004; minimal LA volume: 30.2 ml ± 17.3 ml vs 24 ml ± 10 ml, p = 0.035 in patients with paroxysmal AF, even after adjustment for age, gender, CHA2DS2-VASc score, and stroke severity [p <0.05 for both]). By combining the cut-off values of age, LA emptying fraction, and minimal LA volume the diagnostic accuracy of paroxysmal AF was improved, resulting in a sensitivity of 95% and negative predictive value of 97%. In conclusion, in patients with IS and TIA, LA function measurements (minimal LA volume and LA emptying fraction) are independently associated with paroxysmal AF and may improve risk stratification for paroxysmal AF presence after IS or TIA.
Related Concept Videos
Dysrhythmias V: Evaluating Dysrhythmias
Acute Coronary Syndrome III: Diagnostic Studies
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Rheumatic Heart Disease II: Clinical Manifestations and Diagnostic Studies
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...

